Radiology, Vol 133, 723-725, Copyright © 1979 by Radiological Society of North America
ARTICLES |
BR Williamson, RE McLaughlin, GW Wang, CW Miller, CD Teates and ST Bray
Twenty patients with 23 painful total hip prostheses were examined by radionuclide imaging (20 cases), arthrography (11 cases), needle aspiration (9 cases), and surgery (19 cases) for the purpose of assessing loosening and/or infection. Bone imaging was most accurate, showing three main distributions of activity: (a) ectopic calcification, (b) focal increased activity at the upper and lower ends of the femoral prosthesis, and (c) diffuse activity. These findings suggest that infection and loosening can be differentiated in many instances. None of the patients with focal activity had infection, compared to 2 of the 3 patients with diffuse uptake.
This article has been cited by other articles:
![]() |
O. P. P. Temmerman, P. G. H. M. Raijmakers, J. Berkhof, O. S. Hoekstra, G. J. J. Teule, and I. C. Heyligers Accuracy of diagnostic imaging techniques in the diagnosis of aseptic loosening of the femoral component of a hip prosthesis: A META-ANALYSIS J Bone Joint Surg Br, June 1, 2005; 87-B(6): 781 - 785. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. D. M. Stumpe, H. P. Notzli, M. Zanetti, E. M. Kamel, T. F. Hany, G. W. Gorres, G. K. von Schulthess, and J. Hodler FDG PET for Differentiation of Infection and Aseptic Loosening in Total Hip Replacements: Comparison with Conventional Radiography and Three-Phase Bone Scintigraphy Radiology, May 1, 2004; 231(2): 333 - 341. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |