Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Correction (v171,p878)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Berninger, W. H.
Right arrow Articles by Redington, R. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Berninger, W. H.
Right arrow Articles by Redington, R. W.

Radiology, Vol 138, 711-716, Copyright © 1981 by Radiological Society of North America


ARTICLES

Functional imaging of the brain using computed tomography [published erratum appears in Radiology 1989 Jun;171(3):878]

WH Berninger, L Axel, D Norman, S Napel and RW Redington

Data from rapid-sequence CT scans of the same cross section, obtained following bolus injection of contrast material, were analyzed by functional imaging. The information contained in a large number of images can be compressed into one or two gray-scale images which can be evaluated both qualitatively and quantitatively. The computational techniques are described and applied to the generation of images depicting bolus transit time, arrival time, peak time, and effective width.


This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
F. Gaudiello, V. Colangelo, F. Bolacchi, M. Melis, R. Gandini, F.G. Garaci, V. Cozzolino, R. Floris, and G. Simonetti
Sixty-Four-Section CT Cerebral Perfusion Evaluation in Patients with Carotid Artery Stenosis before and after Stenting with a Cerebral Protection Device
AJNR Am. J. Neuroradiol., May 1, 2008; 29(5): 919 - 923.
[Abstract] [Full Text] [PDF]


Home page
ImagingHome page
G TAN and T GODDARD
Neuroimaging applications of multislice CT perfusion
Imaging, June 1, 2007; 19(2): 142 - 152.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
R. T. Higashida and A. J. Furlan
Trial Design and Reporting Standards for Intra-Arterial Cerebral Thrombolysis for Acute Ischemic Stroke
Stroke, August 1, 2003; 34 (8): e109 - e137.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
A. Apruzzese, M. Silvestrini, R. Floris, F. Vernieri, A. Bozzao, G. Hagberg, C. Caltagirone, S. Masala, and G. Simonetti
Cerebral Hemodynamics in Asymptomatic Patients with Internal Carotid Artery Occlusion: A Dynamic Susceptibility Contrast MR and Transcranial Doppler Study
AJNR Am. J. Neuroradiol., June 1, 2001; 22(6): 1062 - 1067.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
H. C. Roberts, W. P. Dillon, and W. S. Smith
Dynamic CT Perfusion to Assess the Effect of Carotid Revascularization in Chronic Cerebral Ischemia
AJNR Am. J. Neuroradiol., February 1, 2000; 21(2): 421 - 425.
[Abstract] [Full Text]


Home page
Am. J. Neuroradiol.Home page
M. Maeda, W. T. C. Yuh, T. Ueda, J. E. Maley, D. L. Crosby, M.-W. Zhu, and V. A. Magnotta
Severe Occlusive Carotid Artery Disease: Hemodynamic Assessment by MR Perfusion Imaging in Symptomatic Patients
AJNR Am. J. Neuroradiol., January 1, 1999; 20(1): 43 - 51.
[Abstract] [Full Text]


Home page
RadiologyHome page
G. Brix, M. L. Bahner, U. Hoffmann, A. Horvath, and W. Schreiber
Regional Blood Flow, Capillary Permeability, and Compartmental Volumes: Measurement with Dynamic CT—Initial Experience
Radiology, January 1, 1999; 210(1): 269 - 276.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1981 by the Radiological Society of North America.