Radiology, Vol 146, 817-820, Copyright © 1983 by Radiological Society of North America
ARTICLES |
SR Thomas, MJ Gelfand, GS Burns, RC Purdom, JG Kereiakes and HR Maxon
Quantitative conjugate-view external counting techniques were applied to estimate the radiation dose to the liver, spleen, and metaphyseal growth complexes (distal femur and proximal tibia) for ten pediatric patients undergoing gallium-67 scanning procedures. The effective half- life of Ga 67 in these organs was approximately 78 hours. The dose per unit of administered activity for the liver and spleen was between 0.3 and 4.0 rad/mCi (0.08 to 1.08 Gy/GBq) and 0.5 and 7.0 rad/mCi (0.13 to 1.89 Gy/GBq), respectively. For the metaphyseal growth plates, the range was 2.3 to 14.3 rad/mCi (0.62 to 3.86 Gy/GBq).