Radiology, Vol 147, 139-148, Copyright © 1983 by Radiological Society of North America
ARTICLES |
PF New, BR Rosen, TJ Brady, FS Buonanno, JP Kistler, CT Burt, WS Hinshaw, JH Newhouse, GM Pohost and JM Taveras
The risks to patients with metal surgical implants who are undergoing nuclear magnetic resonance (NMR) imaging and the artifacts caused by such implants were studied. Twenty-one aneurysm and other hemostatic clips and a variety of other materials (e.g., dental amalgam, 14 karat gold) were used. Longitudinal forces and torques were found to be exerted upon 16 of the 21 clips. With five aneurysm clips, forces and torques sufficient to produce risk of hemorrhage from dislocation of the clip from the vessel or aneurysm, or cerebral injury by clip displacement without dislodgement were identified. The induced ferromagnetism was shown to be related to the composition of the alloys from which the clips were manufactured. Clips with 10-14% nickel are evidently without sufficient induced ferromagnetism to cause hazard. The extent of NMR imaging artifacts was greater for materials with measurable ferromagnetic properties, but metals without measurable ferromagnetism in our tests also resulted in significant artifacts. Dental amalgam and 14 karat gold produced no imaging artifacts, but stainless steels in dentures and orthodontic braces produced extensive artifacts in the facial region.
This article has been cited by other articles:
![]() |
E. E. Rutherford, L. J. Tarplett, E. M. Davies, J. M. Harley, and L. J. King Lumbar Spine Fusion and Stabilization: Hardware, Techniques, and Imaging Appearances RadioGraphics, November 1, 2007; 27(6): 1737 - 1749. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Patel, G. S. Bhavra, and J. R. S. O'Neill MRI scanning and orthodontics J. Orthod., December 1, 2006; 33(4): 246 - 249. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. M. Lanners, K. K. Amrami, R. S. Jonsgaard, J. J. Gisvold, and J. P. Felmlee Safety and MRI Artifact Evaluation at 1.5 T of Metallic Mounting Sheath of a Marking Clip Inadvertently Deployed at Stereotactic Biopsy Am. J. Roentgenol., September 1, 2004; 183(3): 825 - 829. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. G. Shellock and J. V. Crues MR Procedures: Biologic Effects, Safety, and Patient Care Radiology, September 1, 2004; 232(3): 635 - 652. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. G. Shellock, J. A. Tkach, P. M. Ruggieri, T. J. Masaryk, and P. A. Rasmussen Aneurysm Clips: Evaluation of Magnetic Field Interactions and Translational Attraction by Use of "Long-Bore" and "Short-Bore" 3.0-T MR Imaging Systems AJNR Am. J. Neuroradiol., March 1, 2003; 24(3): 463 - 471. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. A. Finelli, A. R. Rezai, P. M. Ruggieri, J. A. Tkach, J. A. Nyenhuis, G. Hrdlicka, A. Sharan, J. Gonzalez-Martinez, P. H. Stypulkowski, and F. G. Shellock MR Imaging-Related Heating of Deep Brain Stimulation Electrodes: In Vitro Study AJNR Am. J. Neuroradiol., November 1, 2002; 23(10): 1795 - 1802. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. G. Shellock and J. V. Crues III MR Safety and the American College of Radiology White Paper Am. J. Roentgenol., June 1, 2002; 178(6): 1349 - 1352. [Full Text] [PDF] |
||||
![]() |
C. T. Hennemeyer, K. Wicklow, D. A. Feinberg, and C. P. Derdeyn In Vitro Evaluation of Platinum Guglielmi Detachable Coils at 3 T with a Porcine Model: Safety Issues and Artifacts Radiology, June 1, 2001; 219(3): 732 - 737. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Hug, E. Nagel, A. Bornstedt, B. Schnackenburg, H. Oswald, and E. Fleck Coronary Arterial Stents: Safety and Artifacts during MR Imaging Radiology, September 1, 2000; 216(3): 781 - 787. [Abstract] [Full Text] |
||||
![]() |
S. Nishimoto, K. Yoshino, T. Fujii, K. Inakami, M. Nagahara, C. Momohara, T. Terada, and T. Sato Magnetic Resonance Imaging in Patients With Microvascular Anastomotic Devices Arch Otolaryngol Head Neck Surg, September 1, 1999; 125(9): 1033 - 1034. [Full Text] [PDF] |
||||
![]() |
P. R. Hilfiker, H. H. Quick, and J. F. Debatin Plain and Covered Stent-Grafts: In Vitro Evaluation of Characteristics at Three-dimensional MR Angiography Radiology, June 1, 1999; 211(3): 693 - 697. [Abstract] [Full Text] |
||||
![]() |
E. Kanal and F. G. Shellock Aneurysm Clips: Effects of Long-term and Multiple Exposures to a 1.5-T MR System Radiology, February 1, 1999; 210(2): 563 - 565. [Abstract] [Full Text] |
||||
![]() |
M. R. Williamson, T. C. McCowan, C. W. Walker, and E. J. Ferris Effect of a 1.5 Tesla Magnetic Field on Greenfield Filters in Vitro and in Dogs Angiology, January 1, 1988; 39(12): 1022 - 1024. [Abstract] [PDF] |
||||
![]() |
T. Budinger and P. Lauterbur Nuclear magnetic resonance technology for medical studies Science, October 19, 1984; 226(4672): 288 - 298. [Abstract] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |