Radiology, Vol 147, 149-153, Copyright © 1983 by Radiological Society of North America
ARTICLES |
W Pavlicek, M Geisinger, L Castle, GP Borkowski, TF Meaney, BL Bream and JH Gallagher
The effect of nuclear magnetic resonance (NMR) imaging on six representative cardiac pacemakers was studied. The results indicate that the threshold for initiating the asynchronous mode of a pacemaker is 17 gauss. Radiofrequency levels are present in an NMR unit and may confuse or possibly inhibit demand pacemakers, although sensing circuitry is normally provided with electromagnetic interference discrimination. Time-varying magnetic fields can generate pulse amplitudes and frequencies to mimic cardiac activity. A serious limitation in the possibility of imaging a patient with a pacemaker would be the alteration of normal pulsing parameters due to time- varying magnetic fields.
This article has been cited by other articles:
![]() |
A. Roguin, J. Schwitter, C. Vahlhaus, M. Lombardi, J. Brugada, P. Vardas, A. Auricchio, S. Priori, and T. Sommer Magnetic resonance imaging in individuals with cardiovascular implantable electronic devices Europace, March 1, 2008; 10(3): 336 - 346. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. Irnich, B. Irnich, C. Bartsch, W. A. Stertmann, H. Gufler, and G. Weiler Do we need pacemakers resistant to magnetic resonance imaging? Europace, January 1, 2005; 7(4): 353 - 365. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. G. Shellock and J. V. Crues MR Procedures: Biologic Effects, Safety, and Patient Care Radiology, September 1, 2004; 232(3): 635 - 652. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Loewy, A. Loewy, and E. J. Kendall Reconsideration of Pacemakers and MR Imaging RadioGraphics, September 1, 2004; 24(5): 1257 - 1267. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. M. Steiner and J. Loewy Invited Commentary * Author's Response RadioGraphics, September 1, 2004; 24(5): 1267 - 1268. [Full Text] [PDF] |
||||
![]() |
E. T. Martin, J. A. Coman, F. G. Shellock, C. C. Pulling, R. Fair, and K. Jenkins Magnetic resonance imaging and cardiac pacemaker safety at 1.5-Tesla J. Am. Coll. Cardiol., April 7, 2004; 43(7): 1315 - 1324. [Abstract] [Full Text] [PDF] |
||||
![]() |
F Duru, R Luechinger, M.B Scheidegger, T.F Luscher, P Boesiger, and R Candinas Pacing in magnetic resonance imaging environment: Clinical and technical considerations on compatibility Eur. Heart J., January 2, 2001; 22(2): 113 - 124. [PDF] |
||||
![]() |
T. Sommer, C. Vahlhaus, G. Lauck, A. v. Smekal, M. Reinke, U. Hofer, W. Block, F. Träber, C. Schneider, J. Gieseke, et al. MR Imaging and Cardiac Pacemakers: In Vitro Evaluation and in Vivo Studies in 51 Patients at 0.5 T Radiology, June 1, 2000; 215(3): 869 - 879. [Abstract] [Full Text] |
||||
![]() |
I Moseley Safety and magnetic resonance imaging BMJ, May 7, 1994; 308(6938): 1181 - 1182. [Full Text] |
||||
![]() |
T. Budinger and P. Lauterbur Nuclear magnetic resonance technology for medical studies Science, October 19, 1984; 226(4672): 288 - 298. [Abstract] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |