Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Conklin, J. J.
Right arrow Articles by Wagner, H. N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Conklin, J. J.
Right arrow Articles by Wagner, H. N.

Radiology, Vol 147, 221-226, Copyright © 1983 by Radiological Society of North America


ARTICLES

Comparison of bone scan and radiograph sensitivity in the detection of steroid-induced ischemic necrosis of bone

JJ Conklin, PO Alderson, TM Zizic, DS Hungerford, JY Densereaux, A Gober and HN Wagner

A prospective study of bone scanning for detection of ischemic necrosis of bone (INB) was performed in 36 patients (97% female, age range 16-36 yrs.) with systemic lupus erythematosis (SLE). Since the hips, knees, and shoulders are usually affected by INB in patients with SLE, 300 K converging collimator images of these joints were obtained on film and in digital format 2 to 3 hours after the injection of 20 mCi (740 MBq) of Tc-99m methylene diphosphonate. All patients underwent radiography of the joints, and 10 had intraosseous pressure determinations in the marrow space of affected joints (n = 31) for independent assessment of INB. Scans showed abnormally increased joint activity in 28 of the 36 patients. A total of 97 joints showed abnormalities, 19% in the hips, 34% in the knees, and 47% in the shoulders. Twenty-four of 27 joints with elevated bone marrow pressure (BMP) had abnormal scans (sensitivity = 89%), and scans were abnormal in 2 of 4 joints with normal pressures (specificity = 50%). The positive predictive value of the scans compared with BMP measurements was 92% (24/26). Eleven of 27 joints with abnormal BMP had abnormal radiographs, a sensitivity of 41%.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1983 by the Radiological Society of North America.