Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lanzer, P.
Right arrow Articles by Higgins, C. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lanzer, P.
Right arrow Articles by Higgins, C. B.

Radiology, Vol 150, 121-127, Copyright © 1984 by Radiological Society of North America


ARTICLES

Cardiac imaging using gated magnetic resonance

P Lanzer, EH Botvinick, NB Schiller, LE Crooks, M Arakawa, L Kaufman, PL Davis, R Herfkens, MJ Lipton and CB Higgins

To overcome the limitations of magnetic resonance (MR) cardiac imaging using nongated data acquisition, three methods for acquiring a gating signal, which could be applied in the presence of a magnetic field, were tested: an air-filled plethysmograph, a laser-Doppler capillary perfusion flowmeter, and an electrocardiographic gating device. The gating signal was used for timing of MR imaging sequences (IS). Application of each gating method yielded significant improvements in structural MR image resolution of the beating heart, although with both plethysmography and laser-Doppler velocimetry it was difficult to obtain cardiac images from the early portion of the cardiac cycle due to an intrinsic delay between the ECG R wave and peripheral detection of the gating signal. Variations in the temporal relationship between the R wave and plethysmographic and laser-Doppler signals produced inconsistencies in the timing of IS. Since the ECG signal is virtually free of these problems, the preferable gating technique is IS synchronization with an electrocardiogram. The gated images acquired with this method provide sharp definition of internal cardiac morphology and can be temporarily referenced to end diastole and end systole or intermediate points.


This article has been cited by other articles:


Home page
RadiologyHome page
J. C. Carr, O. Simonetti, J. Bundy, D. Li, S. Pereles, and J. P. Finn
Cine MR Angiography of the Heart with Segmented True Fast Imaging with Steady-State Precession
Radiology, June 1, 2001; 219(3): 828 - 834.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. J. Lipton, L. M. Boxt, and Z. M. Hijazi
Role of the Radiologist in Cardiac Diagnostic Imaging
Am. J. Roentgenol., December 1, 2000; 175(6): 1495 - 1506.
[Full Text] [PDF]


Home page
RadioGraphicsHome page
L. M. Boxt
From the RSNA Refresher Courses: Cardiac MR Imaging: A Guide for the Beginner
RadioGraphics, July 1, 1999; 19(4): 1009 - 1025.
[Abstract] [Full Text] [PDF]


Home page
ScienceHome page
T. Budinger and P. Lauterbur
Nuclear magnetic resonance technology for medical studies
Science, October 19, 1984; 226(4672): 288 - 298.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1984 by the Radiological Society of North America.