Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rabinovitch, M. A.
Right arrow Articles by Vogel, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rabinovitch, M. A.
Right arrow Articles by Vogel, R.

Radiology, Vol 150, 813-818, Copyright © 1984 by Radiological Society of North America


ARTICLES

Count-based left ventricular volume determination utilizing a left posterior oblique view for attenuation correction

MA Rabinovitch, V Kalff, K Koral, W Chan, JE Juni, B Lerman, R Lampman, J Walton, D Grassley and R Vogel

This study aimed to determine the inherent error of the left ventricular volume measurement from the gated equilibrium blood pool scintigram utilizing the count-based technique. The study population consisted of 26 patients who had undergone biplane contrast ventriculography. The patients were imaged with a parallel-hole collimator in the left anterior oblique position showing the septum to best advantage. A reference blood sample was counted and radionuclide volumes calculated without correction for attenuation. Attenuation corrected volumes were derived with the factor 1/e-mud, where d = distance from skin marker to center of the left ventricle in the orthogonal left posterior oblique view and mu = linear attenuation coefficient. A series of mu values from 0.08 to 0.15 cm-1 was evaluated. There was a trend toward improvement in the r value and lowering of the SEE with attenuation correction. The tightest 95% confidence limits achieved for an end-diastolic 150-ml ventricle were +/- 44 ml, and for an end-systolic 75-ml ventricle +/- 32 ml. In view of the magnitude of inherent error, the count-based volume measurement may be more suitable for group analyses and in cases in which an individual patient serves as his own control.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1984 by the Radiological Society of North America.