Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nickoloff, E. L.
Right arrow Articles by Alderson, P. O.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nickoloff, E. L.
Right arrow Articles by Alderson, P. O.

Radiology, Vol 152, 511-515, Copyright © 1984 by Radiological Society of North America


ARTICLES

Left ventricular volume: physical basis for attenuation corrections in radionuclide determinations

EL Nickoloff, WH Perman, PD Esser, B Bashist and PO Alderson

Absolute left ventricular volume has been calculated from gated blood pool studies by estimating an attenuation correction for left ventricular counts. We studied the physical basis of these corrections by evaluating x-ray photon attenuation from CT scans of the thorax (10 second scans, no gating). CT numbers were converted to linear attenuation coefficients (LACs) at 140 keV, and LACs from the center of the left ventricle or esophagus to the chest wall (40 degrees left anterior oblique position) were determined in 12 patients of various body habitus. The mean LACs were virtually identical (0.13 cm-1 +/- 0.02 cm-1 SD), but were less than the LAC of water (0.15 cm-1). However, the esophagus was 66% further from the chest wall than the center of the left ventricle. These results suggest that conventional methods overestimate attenuation and show that LAC variability between individuals can be large. Better methods of attenuation correction may improve count-based estimates of left ventricular volume.


This article has been cited by other articles:


Home page
JNMHome page
H. Zaidi and B. Hasegawa
Determination of the Attenuation Map in Emission Tomography
J. Nucl. Med., February 1, 2003; 44(2): 291 - 315.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Endocrinol. Metab.Home page
P. Rotman-Pikielny, J. C. Reynolds, W. C. Barker, P. M. Yen, M. C. Skarulis, and N. J. Sarlis
Recombinant Human Thyrotropin for the Diagnosis and Treatment of a Highly Functional Metastatic Struma Ovarii
J. Clin. Endocrinol. Metab., January 1, 2000; 85(1): 237 - 244.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1984 by the Radiological Society of North America.