Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by McSweeney, M. B.
Right arrow Articles by Goldstein, J. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by McSweeney, M. B.
Right arrow Articles by Goldstein, J. H.

Radiology, Vol 153, 741-744, Copyright © 1984 by Radiological Society of North America


ARTICLES

Magnetic resonance imaging in the diagnosis of breast disease: use of transverse relaxation times

MB McSweeney, WC Small, V Cerny, W Sewell, RW Powell and JH Goldstein

The ability of magnetic resonance imaging (MR) to demonstrate breast carcinoma depends upon significantly different relaxation times in benign and malignant tissues. The authors conducted an in vitro study of transverse relaxation times (T2) of 393 breast tissue samples in order to establish a range of values for normal tissue, benign lesions, and carcinoma. All T2 values were multiexponential. Benign lesions were readily distinguished from both invasive and noninvasive carcinoma in samples containing fat or a mixture of fat and fibrous tissue; however, in purely fibrous samples there was some overlap of T2 values in benign and malignant tissues. Although the data acquisition and analysis requirements involved in this in vitro study exceed the capabilities of present whole-body MR imagers, the added understanding gained through efforts of this type may aid both interpretation of current images and future developments.


This article has been cited by other articles:


Home page
RadioGraphicsHome page
D. R. Rausch and R. E. Hendrick
How to Optimize Clinical Breast MR Imaging Practices and Techniques on Your 1.5-T System
RadioGraphics, September 1, 2006; 26(5): 1469 - 1484.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. A. Jacobs, P. B. Barker, D. A. Bluemke, C. Maranto, C. Arnold, E. H. Herskovits, and Z. Bhujwalla
Benign and Malignant Breast Lesions: Diagnosis with Multiparametric MR Imaging
Radiology, October 1, 2003; 229(1): 225 - 232.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1984 by the Radiological Society of North America.