|
|
||||||||
Radiology, Vol 154, 385-391, Copyright © 1985 by Radiological Society of North America
ARTICLES |
NM Jacobs, EG Grant, D Schellinger, MC Byrd, JD Richardson and SL Cohan
Both carotid bifurcations were examined in 353 patients over a 20-month interval using a combination of real-time and pulsed Doppler ultrasound (duplex scanning). Angiographic correlation was available in 72 cases. Stenosis of the internal carotid was evaluated using a Doppler input frequency of 5 MHz and a scan angle of 60 degrees. A peak frequency shift of less than 3.5 kHz was found to be a sign of less than or equal to 30% stenosis; 3.5-4 kHz with moderate turbulence suggested 31-50% stenosis, 4-8 kHz 51-90% stenosis, and greater than 8 kHz greater than 90% stenosis. Subtotal stenosis (greater than 95%) was manifested by a frequency shift of less than 8 kHz, but the waveform was totally distorted. Overall accuracy improved from 77% for the first 6 months to 87% for the last 14 months. For stenosis greater than 50%, sensitivity improved from 82% to 97% during this period. Analysis of errors and suggestions for avoiding them are presented.
This article has been cited by other articles:
![]() |
G. M. Hathout, J. R. Fink, S. M. El-Saden, and E. G. Grant Sonographic NASCET Index: A New Doppler Parameter for Assessment of Internal Carotid Artery Stenosis AJNR Am. J. Neuroradiol., January 1, 2005; 26(1): 68 - 75. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. M Hathout, M. J. Duh, and S. M. El-Saden Accuracy of Contrast-Enhanced MR Angiography in Predicting Angiographic Stenosis of the Internal Carotid Artery: Linear Regression Analysis AJNR Am. J. Neuroradiol., October 1, 2003; 24(9): 1747 - 1756. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. S. Kriegshauser, M. D. Patel, and K. D. Nelson Carotid Pseudostring Sign From Vasa Vasorum Collaterals J. Ultrasound Med., September 1, 2003; 22(9): 959 - 963. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Koga, K. Kimura, K. Minematsu, and T. Yamaguchi Diagnosis of Internal Carotid Artery Stenosis Greater than 70% with Power Doppler Duplex Sonography AJNR Am. J. Neuroradiol., February 1, 2001; 22(2): 413 - 417. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. G. Grant, A. J. Duerinckx, S. M. El Saden, M. L. Melany, G. M. Hathout, P. T. Zimmerman, A. K. Marumoto, S. N. Cohen, and J. D. Baker Ability to Use Duplex US to Quantify Internal Carotid Arterial Stenoses: Fact or Fiction?1 Radiology, January 1, 2000; 214(1): 247 - 252. [Abstract] [Full Text] |
||||
![]() |
Y. Nagai, E J. Metter, and J. L Fleg Increased carotid artery intimal-medial thickness: risk factor for exercise-induced myocardial ischemia in asymptomatic older individuals Vascular Medicine, August 1, 1999; 4(3): 181 - 186. [Abstract] [PDF] |
||||
![]() |
N. Labropoulos, A. Androulakis, R. Allan, A. D. Giannoukas, E. Touloupakis, T. Tegos, A. Al Kutoubi, and A. N. Nicolaides Value of Color Flow Duplex Imaging in Detection of Subtotal and Total Internal Carotid Artery Occlusion Vascular and Endovascular Surgery, November 1, 1997; 31(6): 775 - 779. [Abstract] [PDF] |
||||
![]() |
N. Suwanwela, U. Can, K. L. Furie, J. F. Southern, N. R. Macdonald, C. S. Ogilvy, C. J. Hansen, F. S. Buonanno, W. M. Abbott, W. J. Koroshetz, et al. Carotid Doppler Ultrasound Criteria for Internal Carotid Artery Stenosis Based on Residual Lumen Diameter Calculated From En Bloc Carotid Endarterectomy Specimens Stroke, November 1, 1996; 27(11): 1965 - 1969. [Abstract] [Full Text] |
||||
![]() |
M. Hirschl, M. Kundi, and G. Blazek Five-Year Follow-up of Patients After Thromboendarterectomy of the Internal Carotid Artery: Relevance of Baroreceptor Sensitivity Stroke, July 1, 1996; 27(7): 1167 - 1172. [Abstract] [Full Text] |
||||
![]() |
B. Griewing, C. Morgenstern, F. Driesner, G. Kallwellis, M.L. Walker, and C. Kessler Cerebrovascular Disease Assessed by Color-Flow and Power Doppler Ultrasonography : Comparison With Digital Subtraction Angiography in Internal CarotidArtery Stenosis Stroke, January 1, 1996; 27(1): 95 - 100. [Abstract] [Full Text] |
||||
![]() |
P. J. Martin, M. E. Gaunt, S. Nydahl, and D. A. Ratliff Diagnosis of Internal Carotid Pseudo-occlusion by Use of Color-Coded Duplex Scanning: A Case Report Vascular and Endovascular Surgery, July 1, 1995; 29(4): 303 - 307. [Abstract] [PDF] |
||||
![]() |
F. Verlato, G.P. Avruscio, D. Milite, G. Salmistraro, G.P. Deriu, and G.P. Signorini Diagnosis of High-Grade Stenosis of Innominate Artery Angiology, November 1, 1993; 44(11): 845 - 851. [Abstract] [PDF] |
||||
![]() |
P. A. Cardullo, B. S. Cutler, and H. B. Wheeler Detection of Carotid Artery Disease by Duplex Ultrasound Journal of Diagnostic Medical Sonography, March 1, 1986; 2(2): 63 - 73. [Abstract] [PDF] |
||||
![]() |
H. W. Poehlmann and L. R. Bigongiari An Introduction to Carotid Duplex Sonography Journal of Diagnostic Medical Sonography, January 1, 1986; 2(1): 2 - 11. [Abstract] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |