Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Correction (v155,p543)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Moran, P. R.
Right arrow Articles by Karstaedt, N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Moran, P. R.
Right arrow Articles by Karstaedt, N.

Radiology, Vol 154, 433-441, Copyright © 1985 by Radiological Society of North America


ARTICLES

Verification and evaluation of internal flow and motion. True magnetic resonance imaging by the phase gradient modulation method

PR Moran, RA Moran and N Karstaedt

We report qualitative and quantitative evaluation and verification studies of the bipolar phase gradient modulation method for true MR imaging of internal flow and motion velocities. Velocity encoding modulations provide speed-of-motion and direction-sensitive images using special phase-sensitive reconstructions. True motion MR imaging does not depend upon subject parameters, T1 or T2, nor upon selective active-volume time-of-flight calculations, nor is it limited strictly to fluid-flow velocities. Conventional MR sequences often induce strong accidental phase gradient modulations that can cause severe artifacts in conventional MR scans and limit the useful sensitivities of true motion MR. Multiple steps of velocity encoding allow resolution of separate elements of the velocity spectrum, and enable suppression of all such phase-artifact difficulties. Some view-to-view phase inconsistencies are intrinsic to the subject being scanned, e.g., strong motion variations during the heart cycle; limitations due to such effects require external modifications in the scanning, such as cardiac gating. Since conventional density information remains in the data, independent of velocity encoding modulations, we suggest a multiple encoding sequence and saving the MR raw data. These evaluations and verifications demonstrate exciting potential in clinical application for the phase gradient modulation method of true flow and motion MR imaging.


This article has been cited by other articles:


Home page
RadioGraphicsHome page
J. Vogel-Claussen, H. Pannu, P. J. Spevak, E. K. Fishman, and D. A. Bluemke
Cardiac Valve Assessment with MR Imaging and 64-Section Multi-Detector Row CT
RadioGraphics, November 1, 2006; 26(6): 1769 - 1784.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
J. Lotz, C. Meier, A. Leppert, and M. Galanski
Cardiovascular Flow Measurement with Phase-Contrast MR Imaging: Basic Facts and Implementation
RadioGraphics, May 1, 2002; 22(3): 651 - 671.
[Abstract] [Full Text] [PDF]


Home page
ScienceHome page
V. Wedeen, R. Meuli, R. Edelman, S. Geller, L. Frank, T. Brady, and B. Rosen
Projective imaging of pulsatile flow with magnetic resonance
Science, November 22, 1985; 230(4728): 946 - 948.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1985 by the Radiological Society of North America.