Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fullerton, G. D.
Right arrow Articles by Ord, V. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fullerton, G. D.
Right arrow Articles by Ord, V. A.

Radiology, Vol 155, 433-435, Copyright © 1985 by Radiological Society of North America


ARTICLES

Orientation of tendons in the magnetic field and its effect on T2 relaxation times

GD Fullerton, IL Cameron and VA Ord

In vitro studies of spin-spin relaxation times of the protons or hydrogen nuclei which make up the tendon demonstrated significant dependence of T2 on orientation at physiological levels of hydration. T2 varied from approximately 250 mu sec. with the tendon aligned with the magnetic field to 22 msec. at an angle of 55 degrees or 125 degrees and 4 msec. at deviations of +/- 15 degrees from 55 degrees and 125 degrees. 55 degrees and 125 degrees are the so-called "magic angles" at which 3 cos2 theta - 1 = 0. As a result, the signal from human tendons in vivo will depend on their orientation; however, T2 is generally short enough that the signal intensity will approach 0 in MR images regardless of the orientation of the tendons, thereby preventing this phenomenon from being observed in most studies.


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
M. P. Recht, D. W. Goodwin, C. S. Winalski, and L. M. White
MRI of Articular Cartilage: Revisiting Current Status and Future Directions
Am. J. Roentgenol., October 1, 2005; 185(4): 899 - 914.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
B. C. Bowen
Peripheral Nerve Imaging and the Magic Angle
AJNR Am. J. Neuroradiol., March 1, 2004; 25(3): 352 - 354.
[Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
K. E. Chappell, M. D. Robson, A. Stonebridge-Foster, A. Glover, J. M. Allsop, A. D. Williams, A. H. Herlihy, J. Moss, P. Gishen, and G. M. Bydder
Magic Angle Effects in MR Neurography
AJNR Am. J. Neuroradiol., March 1, 2004; 25(3): 431 - 440.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
H. Marshall, C. Howarth, D. J. Larkman, A. H. Herlihy, A. Oatridge, and G. M. Bydder
Contrast-Enhanced Magic-Angle MR Imaging of the Achilles Tendon
Am. J. Roentgenol., July 1, 2002; 179(1): 187 - 192.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
T. J. Mosher, H. Smith, B. J. Dardzinski, V. J. Schmithorst, and M. B. Smith
MR Imaging and T2 Mapping of Femoral Cartilage: In Vivo Determination of the Magic Angle Effect
Am. J. Roentgenol., September 1, 2001; 177(3): 665 - 669.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
I. Abe, Y. Harada, K. Oinuma, K. Kamikawa, H. Kitahara, F. Morita, and H. Moriya
Acetabular Labrum: Abnormal Findings at MR Imaging in Asymptomatic Hips
Radiology, August 1, 2000; 216(2): 576 - 581.
[Abstract] [Full Text]


Home page
RadiologyHome page
L. R. Frank, E. C. Wong, W.-M. Luh, J. M. Ahn, and D. Resnick
Articular Cartilage in the Knee: Mapping of the Physiologic Parameters at MR Imaging with a Local Gradient Coil—Preliminary Results
Radiology, January 1, 1999; 210(1): 241 - 246.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1985 by the Radiological Society of North America.