|
|
||||||||
Radiology, Vol 155, 605-606, Copyright © 1985 by Radiological Society of North America
ARTICLES |
AH Newberg, CS Munn and AH Robbins
Arthrography is considered extremely safe since reactions to intraarticular contrast media are rare. We have only seen one severe complication in the performance of more than 2,000 arthrographic procedures. To determine the incidence of complications, a questionnaire was sent to 84 radiologists experienced in arthrography. The 57 respondents had performed more than 126,000 arthrographic procedures, and findings of the survey indicate no deaths, three cases of infection, and 61 cases of hives. Other acute reactions included hypotension, seizures, air embolism, and laryngeal edema. Related complications included sterile chemical synovitis, severe pain after the procedure, and vasovagal reactions.
This article has been cited by other articles:
![]() |
G. Andreisek, S. R. Duc, J. M. Froehlich, J. Hodler, and D. Weishaupt MR Arthrography of the Shoulder, Hip, and Wrist: Evaluation of Contrast Dynamics and Image Quality with Increasing Injection-to-Imaging Time Am. J. Roentgenol., April 1, 2007; 188(4): 1081 - 1088. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. C. Glattes, K. P. Spindler, G. M. Blanchard, M. T. Rohmiller, E. C. McCarty, and J. Block A Simple, Accurate Method to Confirm Placement of Intra-articular Knee Injection Am. J. Sports Med., June 1, 2004; 32(4): 1029 - 1031. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Mutschler, B. C. Vande Berg, F. E. Lecouvet, P. Poilvache, J.-E. Dubuc, B. Maldague, and J. Malghem Postoperative Meniscus: Assessment at Dual-Detector Row Spiral CT Arthrography of the Knee Radiology, September 1, 2003; 228(3): 635 - 641. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. C. Vande Berg, F. E. Lecouvet, P. Poilvache, J.-E. Dubuc, B. Maldague, and J. Malghem Anterior Cruciate Ligament Tears and Associated Meniscal Lesions: Assessment at Dual-Detector Spiral CT Arthrography Radiology, May 1, 2002; (2002) 2232011024. [Abstract] [Full Text] |
||||
![]() |
C. S. Winalski, M. I. Robbins, S. G. Silverman, and J. A.K. Davies Interactive Magnetic Resonance Image-Guided Aspiration Therapy of a Glenoid Labral Cyst : A Case Report J. Bone Joint Surg. Am., August 1, 2001; 83(8): 1237 - 1242. [Full Text] |
||||
![]() |
B. C. Vande Berg, F. E. Lecouvet, P. Poilvache, J.-E. Dubuc, B. Bedat, B. Maldague, J.-J. Rombouts, and J. Malghem Dual-Detector Spiral CT Arthrography of the Knee: Accuracy for Detection of Meniscal Abnormalities and Unstable Meniscal Tears Radiology, September 1, 2000; 216(3): 851 - 857. [Abstract] [Full Text] |
||||
![]() |
H. Bliddal Placement of intra-articular injections verified by mini air-arthrography Ann Rheum Dis, October 1, 1999; 58(10): 641 - 643. [Abstract] [Full Text] |
||||
![]() |
A. J. WILSON, F. A. MANN, and L. A. GILULA Imaging the Hand and Wrist J Hand Surg Eur Vol., April 1, 1990; 15(2): 153 - 167. [PDF] |
||||
![]() |
C. A. Binkert, M. Zanetti, and J. Hodler Patient's Assessment of Discomfort during MR Arthrography of the Shoulder Radiology, December 1, 2001; 221(3): 775 - 778. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. C. Vande Berg, F. E. Lecouvet, P. Poilvache, J.-E. Dubuc, B. Maldague, and J. Malghem Anterior Cruciate Ligament Tears and Associated Meniscal Lesions: Assessment at Dual-Detector Spiral CT Arthrography Radiology, May 1, 2002; 223(2): 403 - 409. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |