Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lanzer, P.
Right arrow Articles by Higgins, C. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lanzer, P.
Right arrow Articles by Higgins, C. B.

Radiology, Vol 155, 681-686, Copyright © 1985 by Radiological Society of North America


ARTICLES

ECG-synchronized cardiac MR imaging: method and evaluation

P Lanzer, C Barta, EH Botvinick, HU Wiesendanger, G Modin and CB Higgins

An electrocardiographic (ECG) sensing and gating device compatible with a 0.35-tesla (T) magnetic resonance (MR) imager has been developed and used to produce 802 MR images of the heart in 30 patients. The instrument consists of an isolated acquisition module, an electrically floating preamplifier, and a monitor gating module. Two spin-echo images were acquired for each of five, 0.7-cm thick, transaxial sections from the base to the apex of the heart during each ECG- synchronized imaging run. Image quality was assessed in a blind study by two investigators, on a scale from 0 to 3, as diagnostic [2-3] or nondiagnostic [0-1]. There was agreement in 91.4% of their assessments of diagnostic images (68.1% of the images studied). Resolution of heart anatomy on the MR images was adversely affected by prolonged spin-echo time delay, imaging in late diastole, image acquisition at the cardiac apex, irregular triggering, and artifacts. The synchronization of gradient pulses to the ECG at 0.35 T appears safe for patients, permits diagnostic resolution of images, allows image acquisition at distinct points during the cardiac cycle, and enables monitoring of patients during imaging.


This article has been cited by other articles:


Home page
RadiologyHome page
J. P. Finn, K. Nael, V. Deshpande, O. Ratib, and G. Laub
Cardiac MR Imaging: State of the Technology.
Radiology, November 1, 2006; 241(2): 338 - 354.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
R. C. Gaba, R. C. Carlos, W. J. Weadock, G. P. Reddy, M. B. Sneider, and P. N. Cascade
Cardiovascular MR Imaging: Technique Optimization and Detection of Disease in Clinical Practice
RadioGraphics, November 1, 2002; 22(6): e6 - e6.
[Abstract] [Full Text]


Home page
RadioGraphicsHome page
L. M. Boxt
From the RSNA Refresher Courses: Cardiac MR Imaging: A Guide for the Beginner
RadioGraphics, July 1, 1999; 19(4): 1009 - 1025.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1985 by the Radiological Society of North America.