Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bobman, S. A.
Right arrow Articles by MacFall, J. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bobman, S. A.
Right arrow Articles by MacFall, J. R.

Radiology, Vol 155, 731-738, Copyright © 1985 by Radiological Society of North America


ARTICLES

Synthesized MR images: comparison with acquired images

SA Bobman, SJ Riederer, JN Lee, SA Suddarth, HZ Wang and JR MacFall

Synthesized and directly acquired spin-echo images were compared in order to assess the validity of magnetic resonance (MR) image synthesis as a method enabling retrospective formation of images by interactive manipulation of scan parameters. Synthetic images subjectively compared favorably in both accuracy and precision with acquired images when formed for the same values of echo (TE) and repetition times (TR) and for interpolated and extrapolated values of both TE and TR. Plots of synthetic and acquired signals within the same pixel sectors quantitatively showed comparable values for several regions of interest in the brain. Percent error and noise-normalized differences between acquired and synthetic images were tested as a quantitative measure of accuracy. Percent error was consistently less than 5% for brain parenchyma, and synthetic signals were accurate to within four times the noise level at acquisition. The apparent signal-to-noise ratio of synthetic images was comparable, superior, or inferior to similar acquired images, depending on the values of TE and TR. Total acquisition time required for synthetic formation of images for arbitrary values of TE and TR was equivalent to that of a single direct acquisition with a TR of 2,500 msec.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1985 by the Radiological Society of North America.