|
|
||||||||
Radiology, Vol 156, 69-72, Copyright © 1985 by Radiological Society of North America
ARTICLES |
KC Wright, S Wallace, C Charnsangavej, CH Carrasco and C Gianturco
Percutaneous, expanding, endovascular stents were constructed of stainless steel wire formed in a zig-zag pattern. Stents were placed for varying periods of time in the jugular vein, vena cava, and abdominal aorta in each of five adult dogs. The dilating force of the stents could be controlled by different wire size, number and angle of wire bends, and stent length. In addition, multiple stents could be placed one inside the other or one after the other, depending on the circumstance. The stents distended the vessels and increased their diameter. No flow defects, luminal narrowing, or occlusion were noted in any of the stented vessels, even after 6 months. Side branches bridged by the stents remained patent and showed no indication of narrowing. Stent wires became encased by a proliferation of the tunica intima where they contacted the vessel wall. Encasement was slower and less extensive in the abdominal aorta. No vascular erosion or clot formation was found to be associated with any of the stents.
This article has been cited by other articles:
![]() |
C. E. Dauphine, P. Tan, R. W. Beart Jr., P. Vukasin, H. Cohen, and M. L. Corman Placement of Self-Expanding Metal Stents for Acute Malignant Large-Bowel Obstruction: A Collective Review Ann. Surg. Oncol., July 1, 2002; 9(6): 574 - 579. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. C. Robey, T. Valimaa, H. S. Murphy, P. Tormala, D. J. Mooney, and R. A. Weatherly Use of Internal Bioabsorbable PLGA "Finger-Type" Stents in a Rabbit Tracheal Reconstruction Model Arch Otolaryngol Head Neck Surg, August 1, 2000; 126(8): 985 - 991. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. W. ROBERTS and S. W. REDDING CORONARY ARTERY STENTS: REVIEW AND PATIENT-MANAGEMENT RECOMMENDATIONS J Am Dent Assoc, June 1, 2000; 131(6): 797 - 801. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Kitagami, T. Takahashi, S. Watanabe, O. Suzuki, T. Morikawa, S.-i. Okushiba, and H. Katoh Experimental study of tracheal patch reconstruction with a covered expandable metallic stent Ann. Thorac. Surg., November 1, 1998; 66(5): 1777 - 1781. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. N. Ruygrok and P. W. Serruys Intracoronary Stenting: From Concept to Custom Circulation, September 1, 1996; 94(5): 882 - 890. [Full Text] |
||||
![]() |
R. Shah, S. Sabanathan, R. A. Lowe, and A. J. Mearns STENTING IN MALIGNANT OBSTRUCTION OF SUPERIOR VENA CAVA J. Thorac. Cardiovasc. Surg., August 1, 1996; 112(2): 335 - 340. [Abstract] [Full Text] |
||||
![]() |
M. Kato, T. Matsuda, M. Kaneko, T. Ueda, T. Kuratani, Y. Yoshioka, and K. Ohnishi Experimental Assessment of Newly Devised Transcatheter Stent-Graft for Aortic Dissection Ann. Thorac. Surg., April 1, 1995; 59(4): 908 - 914. [Abstract] [Full Text] |
||||
![]() |
V. Mickley, J. M. Friedrich, N. Rilinger, M. Storck, and D. Abendroth PTA Plus Stent Implantation Versus PTA Alone for Central Venous Stenoses Vascular and Endovascular Surgery, October 1, 1994; 28(8): 505 - 512. [Abstract] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |