Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Palmaz, J. C.
Right arrow Articles by Rice, W. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Palmaz, J. C.
Right arrow Articles by Rice, W. J.

Radiology, Vol 156, 73-77, Copyright © 1985 by Radiological Society of North America


ARTICLES

Expandable intraluminal graft: a preliminary study. Work in progress

JC Palmaz, RR Sibbitt, SR Reuter, FO Tio and WJ Rice

To overcome the problem of recurrence of stenosis after vascular balloon dilatations, we developed an expandable, intraluminal graft that allows dilatation of the lesion and simultaneous placement of a supportive endoprosthesis to prevent recoil of the arterial wall. The graft is made of continuous, woven, stainless steel wire. The resulting tubular mesh has a wall thickness of 200-450 micron and 80% open surface. The grafts, mounted on angioplasty catheters, are introduced through 8-12-F Teflon sheaths. Eleven grafts of 6, 8, and 10 mm in diameter by 20 mm long were placed in the aorta, common carotid, superior mesenteric, iliac, and renal arteries of dogs. Six grafts showed no stenosis in follow-up studies of up to 8 weeks. Two grafts had moderate stenosis as a result of neointimal hyperplasia. Two partial and one complete graft thrombosis occurred in nonheparinized animals in which the graft outflow was restricted. Anticoagulant was not used on a long-term basis. Light and electron microscopy studies showed complete covering of the graft's inner surface by endothelium at 3 weeks.


This article has been cited by other articles:


Home page
NEJMHome page
P. W. Serruys, M. J.B. Kutryk, and A. T.L. Ong
Coronary-Artery Stents
N. Engl. J. Med., February 2, 2006; 354(5): 483 - 495.
[Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
J. B. Pillai, J. Smith, A. Hasan, and D. Spencer
Review of pediatric airway malacia and its management, with emphasis on stenting
Eur. J. Cardiothorac. Surg., January 1, 2005; 27(1): 35 - 44.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
P. H. Grewe, T. Deneke, A. Machraoui, J.u. Barmeyer, and K.-M. Muller
Acute and chronic tissue response to coronary stent implantation: pathologic findings in human specimen
J. Am. Coll. Cardiol., January 1, 2000; 35(1): 157 - 163.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
R. Komatsu, M. Ueda, T. Naruko, A. Kojima, and A. E. Becker
Neointimal Tissue Response at Sites of Coronary Stenting in Humans : Macroscopic, Histological, and Immunohistochemical Analyses
Circulation, July 21, 1998; 98(3): 224 - 233.
[Abstract] [Full Text] [PDF]


Home page
Arch. Dis. Child.Home page
K. P WALSH
Interventional cardiology
Arch. Dis. Child., January 1, 1997; 76(1): 6 - 8.
[Full Text]


Home page
CirculationHome page
P. N. Ruygrok and P. W. Serruys
Intracoronary Stenting: From Concept to Custom
Circulation, September 1, 1996; 94(5): 882 - 890.
[Full Text]


Home page
CirculationHome page
S. B. King III
Angioplasty From Bench to Bedside to Bench
Circulation, May 1, 1996; 93(9): 1621 - 1629.
[Full Text]


Home page
CirculationHome page
F. F. Ing, R. G. Grifka, M. R. Nihill, and C. E. Mullins
Repeat Dilation of Intravascular Stents in Congenital Heart Defects
Circulation, August 15, 1995; 92(4): 893 - 897.
[Abstract] [Full Text]


Home page
CirculationHome page
C. E. Ruiz, H. P. Zhang, J. T. Douglas, C. W. Zuppan, and C. J.C. Kean
A Novel Method for Treatment of Abdominal Aortic Aneurysms Using Percutaneous Implantation of a Newly Designed Endovascular Device
Circulation, May 1, 1995; 91(9): 2470 - 2477.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
M. Kato, T. Matsuda, M. Kaneko, T. Ueda, T. Kuratani, Y. Yoshioka, and K. Ohnishi
Experimental Assessment of Newly Devised Transcatheter Stent-Graft for Aortic Dissection
Ann. Thorac. Surg., April 1, 1995; 59(4): 908 - 914.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1985 by the Radiological Society of North America.