Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gunther, R. W.
Right arrow Articles by Storkel, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gunther, R. W.
Right arrow Articles by Storkel, S.

Radiology, Vol 156, 315-320, Copyright © 1985 by Radiological Society of North America


ARTICLES

Vena caval filter to prevent pulmonary embolism: experimental study. Work in progress

RW Gunther, H Schild, A Fries and S Storkel

A new inferior vena caval filter was tested in an experimental series of 23 dogs and in an in vitro study. The filter consists of a pliable basket and anchoring legs made of stainless steel. It can be inserted percutaneously in an antegrade or retrograde fashion through a 10-F Teflon catheter and can be retrieved with a snare or forceps. The filter is self-orienting in the inferior vena cava, becomes securely the inferior vena cava, becomes securely fixed to the wall, and has exhibited no tendency to migrate. It is highly effective in capturing small and large emboli. There was no significant elevation in upstream hydrostatic pressure following entrapment of emboli. Spontaneous thrombus formation within the basket was observed in two of six dogs who had short-term follow-up. In dogs who had long-term follow-up, the filter remained patent. Microscopically, the filter caused sclerosis of the intima where the wire was in contact with the vessel wall. Breakage of an anchor leg and separation at the fusion between anchor and basket were seen in the study. They were eliminated by improvement of the prototype, which is now ready for clinical application.


This article has been cited by other articles:


Home page
VASC ENDOVASCULAR SURGHome page
S.-i. Watanabe, S. Shimokawa, Y. Moriyama, M. Koga, Y. Iguro, H. Masuda, A. Yamaoka, Y. Fukumoto, K.-i. Sakasegawa, H. Saigenji, et al.
Clinical Experience with Temporary Vena Cava Filters
Vascular and Endovascular Surgery, July 1, 2001; 35(4): 285 - 290.
[Abstract] [PDF]


Home page
ANGIOLOGYHome page
M. R. Williamson, T. C. McCowan, C. W. Walker, and E. J. Ferris
Effect of a 1.5 Tesla Magnetic Field on Greenfield Filters in Vitro and in Dogs
Angiology, January 1, 1988; 39(12): 1022 - 1024.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1985 by the Radiological Society of North America.