Radiology, Vol 157, 391-393, Copyright © 1985 by Radiological Society of North America
ARTICLES |
CF Tate 3d, HR Wilkov, NR Lestrange, HF Gardiner and KR Stein
Seventy-nine patients underwent lumbar myelography on an outpatient basis, with a low (3.75 g) dose of metrizamide as the radiocontrast agent and a 25-gauge spinal needle used for lumbar puncture. No patient experienced significant neurotoxicity following the examination; 70.8% (56 of 79) experienced minimal (23%) or no (48%) side effects. Three patients (3.8%) were admitted to the hospital for management of common side effects (headache, nausea/vomiting, back pain). We obtained postmyelographic computed tomographic scans on 96% (76 of 79) of the patients. Our initial results suggest that outpatient lumbar myelography is safe and can be performed with a very acceptable incidence of side effects.
This article has been cited by other articles:
![]() |
S. D. BODEN Current Concepts Review - The Use of Radiographic Imaging Studies in the Evaluation of Patients Who Have Degenerative Disorders of the Lumbar Spine J. Bone Joint Surg. Am., January 1, 1996; 78(1): 114 - 24. [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |