Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Greif, W. L.
Right arrow Articles by Brady, T. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Greif, W. L.
Right arrow Articles by Brady, T. J.

Radiology, Vol 157, 461-466, Copyright © 1985 by Radiological Society of North America


ARTICLES

Pulse sequence optimization for MR imaging using a paramagnetic hepatobiliary contrast agent

WL Greif, RB Buxton, RB Lauffer, S Saini, DD Stark, VJ Wedeen, BR Rosen and TJ Brady

Paramagnetic agents enhance contrast between tissues in magnetic resonance (MR) imaging by altering tissue relaxation times. The effect of these changes on MR image intensity depends in part on the choice of operator-controlled pulse sequence parameters. With the newly described paramagnetic hepatobiliary contrast agent, iron(III) ethylenebis-(2- hydroxyphenylglycine), Fe(EHPG)-, an in vivo experimental analysis of pulse sequence optimization was performed on the rat. We compared the enhancement of the liver divided by background noise, EL/N, of standard inversion-recovery (IR) and spin-echo (SE) T1-weighted pulse sequences and several pulse sequences theoretically predicted to have improved EL/N. Optimization of the echo time (TE = TEmin) gave a substantial (greater than 60%) increase in EL/N over the standard IR and SE pulse sequences. Images obtained with optimized repetition rate and inversion time gave only a slight additional improvement. Within the uncertainties of our relaxation measurements, the measured changes in EL/N with pulse sequence optimization corresponded well with theoretical predictions. With the experimental and theoretical data, the importance of using a short echo time to obtain maximal T1 contrast in contrast-enhanced MR imaging and the relative merits of optimized SE versus IR pulse sequences for contrast-enhanced MR imaging are discussed.


This article has been cited by other articles:


Home page
Proc. Natl. Acad. Sci. USAHome page
E. T. Ahrens, U. Rothbacher, R. E. Jacobs, and S. E. Fraser
A model for MRI contrast enhancement using T1 agents
PNAS, July 21, 1998; 95(15): 8443 - 8448.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1985 by the Radiological Society of North America.