|
|
||||||||
Radiology, Vol 157, 589-593, Copyright © 1985 by Radiological Society of North America
ARTICLES |
P Gamble, RF Colapinto, RD Stronell, JC Colman and L Blendis
Transjugular liver biopsy was performed in a large series of patients for whom routine percutaneous biopsy was contraindicated; most of the patients had severe liver disease associated with coagulopathies or massive ascites. Of the 461 biopsies performed over a 7-year period, adequate specimens for histologic diagnosis were obtained in 425; in 14 (3.3%), the biopsy provided a false-negative result. Minor complications such as neck pain, hematoma at the puncture site, or pyrexia occurred in 79 patients (17.1%). Serious complications were encountered in six patients (1.3%) (two with cardiac arrhythmias; four with intraperitoneal hemorrhage following capsular perforation), with an overall mortality rate for the series of 0.22%. Modification of the technique--taking the biopsy with the catheter positioned centrally rather than wedged peripherally--has reduced the occurrence of capsular perforation without affecting the success rate. Transjugular liver biopsy is a valuable technique that provides diagnostic information in a high proportion of cases in which conventional percutaneous biopsy is contraindicated.
This article has been cited by other articles:
![]() |
E Cholongitas, A Quaglia, D Samonakis, M Senzolo, C Triantos, D Patch, G Leandro, A P Dhillon, and A K Burroughs Transjugular liver biopsy: how good is it for accurate histological interpretation? Gut, December 1, 2006; 55(12): 1789 - 1794. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Habdank, R. Restrepo, V. Ng, B. L. Connolly, M. J. Temple, J. Amaral, and P. G. Chait Combined Sonographic and Fluoroscopic Guidance During Transjugular Hepatic Biopsies Performed in Children: A Retrospective Study of 74 Biopsies Am. J. Roentgenol., May 1, 2003; 180(5): 1393 - 1398. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. P. Smith, T. L. Presson, M. A. Heneghan, and J. M. Ryan Transjugular Biopsy of the Liver in Pediatric and Adult Patients Using an 18-Gauge Automated Core Biopsy Needle: A Retrospective Review of 410 Consecutive Procedures Am. J. Roentgenol., January 1, 2003; 180(1): 167 - 172. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. J. Roche, W. K. Lee, V. A. Duddalwar, S. Nicolaou, P. L. Munk, and D. C. Morris Intrahepatic Pseudoaneurysm Complicating Transjugular Biopsy of the Liver Am. J. Roentgenol., October 1, 2001; 177(4): 819 - 821. [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |