Radiology, Vol 158, 11-19, Copyright © 1986 by Radiological Society of North America
ARTICLES |
PM Lams and ML Cocklin
Thirty-eight selected clinical radiographs were digitized and displayed on a 1,024-line monitor at pixel sizes of 1.6, 0.8, 0.4, and 0.2 mm. Eighteen experienced radiologists assessed the radiographs and digital images, which included 12 examples of abnormal solitary nodular density, ten examples of septal lines, and 16 controls, six of which showed diffuse lung abnormalities. For each level of spatial resolution and for film reading, observers gave their decision confidence on a sliding scale of probability. Receiver operating characteristic curves were generated from these data. It was found that while spatial resolution requirements for solitary nodules were not critical for pixel sizes at or below 0.8 mm, the requirement for septal lines was likely to be 0.4 mm (1.25 line pairs/mm).
This article has been cited by other articles:
![]() |
M. Zahringer, V. Hesselmann, O. Schulte, K. F. Kamm, W. Braun, G. Haupt, B. Krug, and K. Lackner Reducing the Radiation Dose During Excretory Urography: Flat-Panel Silicon X-Ray Detector Versus Computed Radiography Am. J. Roentgenol., October 1, 2003; 181(4): 931 - 937. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. M. Goo, J.-G. Im, H. J. Lee, M. J. Chung, J. B. Seo, H. Y. Kim, Y.-J. Lee, J.-W. Kang, and J. H. Kim Detection of Simulated Chest Lesions by Using Soft-Copy Reading: Comparison of an Amorphous Silicon Flat-Panel-Detector System and a Storage-Phosphor System Radiology, July 1, 2002; 224(1): 242 - 246. [Abstract] [Full Text] |
||||
![]() |
M. Zahringer, B. Krug, K.-F. Kamm, G. Wassmer, M. Hellmich, G. Winnekendonk, J. Andermahr, A. Go{beta}mann, and K. J. Lackner Detection of Porcine Bone Lesions and Fissures: Comparing Digital Selenium, Digital Luminescence, and Analog Film-Screen Radiography Am. J. Roentgenol., December 1, 2001; 177(6): 1397 - 1403. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. W. Goo, H. J. Kim, K.-S. Song, E. A.-R. Kim, K. S. Kim, C. H. Yoon, and S. Y. Pi Using Edge Enhancement to Identify Subtle Findings on Soft-Copy Neonatal Chest Radiographs Am. J. Roentgenol., August 1, 2001; 177(2): 437 - 440. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. P. M. Miró, A. N. Leung, G. D. Rubin, Y. H. Choi, S. T. Kee, R. E. Mindelzun, P. Stark, L. Wexler, S. K. Plevritis, and B. J. Betts Digital Storage Phosphor Chest Radiography: An ROC Study of the Effect of 2K versus 4K Matrix Size on Observer Performance Radiology, February 1, 2001; 218(2): 527 - 532. [Abstract] [Full Text] |
||||
![]() |
E. J. Potchen, T. G. Cooper, A. E. Sierra, G. R. Aben, M. J. Potchen, M. G. Potter, and J. E. Siebert Measuring Performance in Chest Radiography Radiology, November 1, 2000; 217(2): 456 - 459. [Abstract] [Full Text] |
||||
![]() |
J. Shiraishi, S. Katsuragawa, J. Ikezoe, T. Matsumoto, T. Kobayashi, K.-i. Komatsu, M. Matsui, H. Fujita, Y. Kodera, and K. Doi Development of a Digital Image Database for Chest Radiographs With and Without a Lung Nodule: Receiver Operating Characteristic Analysis of Radiologists' Detection of Pulmonary Nodules Am. J. Roentgenol., January 1, 2000; 174(1): 71 - 74. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. A. Halvorsen and I. S. Kristiansen Radiology services for remote communities: cost minimisation study of telemedicine BMJ, May 25, 1996; 312(7042): 1333 - 1336. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |