|
|
||||||||
Radiology, Vol 160, 463-467, Copyright © 1986 by Radiological Society of North America
ARTICLES |
H Koenig, D Lucas and R Meissner
Excellent spatial resolution is required to demonstrate the complex region of the wrist, with its diverse structures comprising bone, cartilage, and ligaments. Magnetic resonance (MR) imaging was done with a Magnetom imaging system operating at 1.0 T. Use of a flat surface coil enabled excellent spatial resolution and a section thickness of 4 mm. Twenty-nine patients with navicular nonunion or pseudarthrosis, rheumatoid arthritis, recent fractures, soft-tissue alterations, and bone tumors were examined. All patients had undergone radiography and bone scintigraphy. In this limited sampling, MR was found to detect and characterize marrow and articular alterations more accurately, and earlier, than either of those modalities.
This article has been cited by other articles:
![]() |
F M McQueen A vital clue to deciphering bone pathology: MRI bone oedema in rheumatoid arthritis and osteoarthritis Ann Rheum Dis, December 1, 2007; 66(12): 1549 - 1552. [Full Text] [PDF] |
||||
![]() |
M Backhaus, G R Burmester, D Sandrock, D Loreck, D Hess, A Scholz, S Blind, B Hamm, and M Bollow Prospective two year follow up study comparing novel and conventional imaging procedures in patients with arthritic finger joints Ann Rheum Dis, October 1, 2002; 61(10): 895 - 904. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Borthakur, E. M. Shapiro, S. V. S. Akella, A. Gougoutas, J. B. Kneeland, and R. Reddy Quantifying Sodium in the Human Wrist in Vivo by Using MR Imaging Radiology, August 1, 2002; 224(2): 598 - 602. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. SHIONOYA, R. NAKAMURA, T. IMAEDA, and N. MAKINO Arthrography is Superior to Magnetic Resonance Imaging for Diagnosing Injuries of the Triangular Fibrocartilage J Hand Surg Eur Vol., June 1, 1998; 23(3): 402 - 405. [Abstract] [PDF] |
||||
![]() |
J. LEPISTO, K. MATTILA, S. NIEMINEN, B. SATTLER, and M. KORMANO Low Field MRI and Scaphoid Fracture J Hand Surg Eur Vol., August 1, 1995; 20(4): 539 - 542. [Abstract] [PDF] |
||||
![]() |
M. SAKUMA, R. NAKAMURA, and T. IMAEDA Analysis of Proximal Fragment Sclerosis and Surgical Outcome of Scaphoid Non-Union by Magnetic Resonance Imaging J Hand Surg Eur Vol., April 1, 1995; 20(2): 201 - 205. [Abstract] [PDF] |
||||
![]() |
S. YOSHIOKA, Y. OKUDA, K. TAMAI, Y. HIRASAWA, and Y. KODA Changes in Carpal Tunnel Shape During Wrist Joint Motion: MRI evaluation of normal volunteers J Hand Surg Eur Vol., October 1, 1993; 18(5): 620 - 623. [Abstract] [PDF] |
||||
![]() |
T. IMAEDA, R. NAKAMURA, T. MIURA, and N. MAKINO Magnetic Resonance Imaging in Kienbock's Disease J Hand Surg Eur Vol., February 1, 1992; 17(1): 12 - 19. [Abstract] [PDF] |
||||
![]() |
T. IMAEDA, R. NAKAMURA, T. MIURA, and N. MAKINO Magnetic Resonance Imaging in Scaphoid Fractures J Hand Surg Eur Vol., February 1, 1992; 17(1): 20 - 27. [Abstract] [PDF] |
||||
![]() |
A. J. WILSON, F. A. MANN, and L. A. GILULA Imaging the Hand and Wrist J Hand Surg Eur Vol., April 1, 1990; 15(2): 153 - 167. [PDF] |
||||
![]() |
C. HEALY, J. D. WATSON, A. LONGSTAFF, and M. J. CAMPBELL Magnetic Resonance Imaging of the Carpal Tunnel J Hand Surg Eur Vol., April 1, 1990; 15(2): 243 - 248. [Abstract] [PDF] |
||||
![]() |
G. CRISTIANI, E. CEROFOLINI, P. B. SQUARZINA, S. ZANASI, A. LEONI, R. ROMAGNOLI, and A. CAROLI Evaluation of Ischaemic Necrosis of Carpal Bones by Magnetic Resonance Imaging J Hand Surg Eur Vol., April 1, 1990; 15(2): 249 - 255. [Abstract] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |