Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Henkelman, R. M.
Right arrow Articles by Bronskill, M. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Henkelman, R. M.
Right arrow Articles by Bronskill, M. J.

Radiology, Vol 161, 727-734, Copyright © 1986 by Radiological Society of North America


ARTICLES

Optimal pulse sequence for imaging hepatic metastases

RM Henkelman, P Hardy, PY Poon and MJ Bronskill

For magnetic resonance (MR) imaging studies in which the diagnosis is dependent on image contrast, it is essential that an optimized imaging technique be used. Using detection of hepatic metastases as an example, the authors describe a rational strategy for optimizing MR imaging technique. First, for a single patient with proved hepatic metastases, a variety of imaging sequences is discussed and evaluated, leading to characterization of the patient's hepatic tissues. Then the characteristics of the tissues of a representative patient population are presented. These are used to determine two optimal pulse sequences that maximize the achievable signal difference-to-noise ratio achievable in a fixed imaging time. The recommended imaging sequence for detection of hepatic metastases at 0.15 T is either a three- dimensional volume spin-echo (SE) sequence with echo time (TE) = 12 msec and repetition time (TR) = 184 msec or a multisection inversion recovery sequence with TE = 22 msec, inversion time = 250 msec, and TR = 1,375 msec. The variation of this optimum pulse sequence with field strength is also presented.


This article has been cited by other articles:


Home page
RadiologyHome page
S. J. Graham and R. M. Henkelman
Pulsed Magnetization Transfer Imaging: Evaluation of Technique
Radiology, September 1, 1999; 212(3): 903 - 910.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1986 by the Radiological Society of North America.