|
|
||||||||
Radiology, Vol 162, 31-38, Copyright © 1987 by Radiological Society of North America
ARTICLES |
KJ Taylor, SS Morse, CM Rigsby, M Bia and M Schiff
Renal allografts are subject to many vascular complications. Over a 2- year period, 334 duplex Doppler ultrasonographic (US) examinations were performed in 88 renal allograft recipients. Vascular occlusion on the basis of severe vascular rejection was documented in ten patients (11.4%) for a sensitivity and specificity of 100%. Seven patients, for whom there was clinical and Doppler US evidence for renal artery stenosis, underwent angiography. A significant stenosis was confirmed and treated by angioplasty in four patients; one had an insignificant stenosis in an accessory artery, one had kinking of the renal vessels, and another had normal findings. The most reliable criteria for stenosis were a high-velocity jet exceeding 7.5 kHz and distal turbulence. One arteriovenous fistula was diagnosed by the presence of an intrarenal high-velocity jet. Duplex Doppler US is a useful, noninvasive, and portable initial procedure with which to screen patients for vascular complications of renal transplantation.
This article has been cited by other articles:
![]() |
S. B. Park, J. K. Kim, and K.-S. Cho Complications of Renal Transplantation: Ultrasonographic Evaluation J. Ultrasound Med., May 1, 2007; 26(5): 615 - 633. [Abstract] [Full Text] [PDF] |
||||
![]() |
G M Baxter Imaging and renal transplantation Imaging, August 1, 2002; 14(4): 285 - 298. [Full Text] [PDF] |
||||
![]() |
E. D. Brown, M. Y. M. Chen, N. T. Wolfman, D. J. Ott, and N. E. Watson Jr Complications of Renal Transplantation: Evaluation with US and Radionuclide Imaging RadioGraphics, May 1, 2000; 20(3): 607 - 622. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. B. Newberry and R. C. Nelson Duplex Sonography in the Evaluation of Pancreas Transplants Journal of Diagnostic Medical Sonography, March 1, 1991; 7(2): 74 - 80. [Abstract] [PDF] |
||||
![]() |
A. M. de Gaetano, G. Boldrini, G. Nanni, F. Serino, I. Giovannini, and M. Castagneto Noninvasive Surveillance of Allografted Kidneys by Ultrasonic Duplex Scanning Angiology, August 1, 1989; 40(8): 705 - 715. [Abstract] [PDF] |
||||
![]() |
G. L. Moneta, D. C. Taylor, R. A. Yeager, and J. M. Porter Duplex Ultrasound: Applications to Intra-abdominal Vessels Perspectives in Vascular Surgery and Endovascular Therapy, January 1, 1989; 2(2): 133 - 148. [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |