Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Aberle, D. R.
Right arrow Articles by Golden, J. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Aberle, D. R.
Right arrow Articles by Golden, J. A.

Radiology, Vol 165, 351-353, Copyright © 1987 by Radiological Society of North America


ARTICLES

Fatal systemic arterial air embolism following lung needle aspiration

DR Aberle, G Gamsu and JA Golden
Department of Radiological Sciences, UCLA Medical Center 90024.

Fatal systemic arterial air embolism occurred as a complication of percutaneous fine-needle aspiration of the lung, immediately following cytologic sampling of a vasculitic lesion of Wegener granulomatosis. This complication is extremely rare, and it may have been caused by the biopsy of abnormal veins, in which transmural inflammation prevented the normal vasoconstrictive responses to injury.


This article has been cited by other articles:


Home page
ChestHome page
T. Hiraki, H. Fujiwara, J. Sakurai, T. Iguchi, H. Gobara, N. Tajiri, H. Mimura, and S. Kanazawa
Nonfatal Systemic Air Embolism Complicating Percutaneous CT-Guided Transthoracic Needle Biopsy: Four Cases From a Single Institution
Chest, August 1, 2007; 132(2): 684 - 690.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
C. A. Meyer
"Transthoracic Needle Aspiration Biopsy of Benign and Malignant Lung Lesions"--A Commentary
Am. J. Roentgenol., April 1, 2007; 188(4): 891 - 893.
[Full Text] [PDF]


Home page
ChestHome page
Y. Schwarz, J. Greif, H. D. Becker, A. Ernst, and A. Mehta
Real-Time Electromagnetic Navigation Bronchoscopy to Peripheral Lung Lesions Using Overlaid CT Images: The First Human Study.
Chest, April 1, 2006; 129(4): 988 - 994.
[Abstract] [Full Text] [PDF]


Home page
ICVTSHome page
N. Sawabata, S. Yokota, H. Maeda, M. Nakagawa, T. Yamaguchi, T. Okada, and M. Itho
Diagnosis of solitary pulmonary nodule: optimal strategy based on nodal size
Interactive CardioVascular and Thoracic Surgery, April 1, 2006; 5(2): 105 - 108.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
S. Sasada, Y. Ogata, M. Kobayashi, T. Hirashima, K. Kawahara, K. Matsui, and I. Kawase
Angled Forceps Used for Transbronchial Biopsy in Which Standard Forceps Are Difficult To Manipulate: A Comparative Study
Chest, March 1, 2006; 129(3): 725 - 733.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
G. Y. Jin, J. M. Lee, Y. C. Lee, and Y. M. Han
Acute Cerebral Infarction After Radiofrequency Ablation of an Atypical Carcinoid Pulmonary Tumor
Am. J. Roentgenol., April 1, 2004; 182(4): 990 - 992.
[Full Text] [PDF]


Home page
ChestHome page
N. Shinagawa, K. Yamazaki, Y. Onodera, K. Miyasaka, E. Kikuchi, H. Dosaka-Akita, and M. Nishimura
CT-Guided Transbronchial Biopsy Using an Ultrathin Bronchoscope With Virtual Bronchoscopic Navigation
Chest, March 1, 2004; 125(3): 1138 - 1143.
[Abstract] [Full Text] [PDF]


Home page
ThoraxHome page
A Manhire, M Charig, C Clelland, F Gleeson, R Miller, H Moss, K Pointon, C Richardson, and E Sawicka
Guidelines for radiologically guided lung biopsy
Thorax, November 1, 2003; 58(11): 920 - 936.
[Full Text] [PDF]


Home page
Br. J. Radiol.Home page
C M Richardson, K S Pointon, A R Manhire, and J T Macfarlane
Percutaneous lung biopsies: a survey of UK practice based on 5444 biopsies
Br. J. Radiol., September 1, 2002; 75(897): 731 - 735.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
B. Mokhlesi, I. Ansaarie, M. Bader, M. Tareen, and J. Boatman
Coronary Artery Air Embolism Complicating a CT-Guided Transthoracic Needle Biopsy of the Lung
Chest, March 1, 2002; 121(3): 993 - 996.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. E. Silberzweig, C. Hilfer, and E. K. Lang
Embolization of an Autologous Clot Dr Lang responds:
Radiology, May 1, 2001; 219(2): 574 - 574.
[Full Text]


Home page
RadiologyHome page
E. K. Lang, R. Ghavami, V. C. Schreiner, S. Archibald, and J. Ramirez
Autologous Blood Clot Seal to Prevent Pneumothorax at CT-guided Lung Biopsy
Radiology, July 1, 2000; 216(1): 93 - 96.
[Abstract] [Full Text]


Home page
Rheumatology (Oxford)Home page
D. M. Carruthers, S. Connor, A. J. Howie, A. R. Exley, K. Raza, P. A. Bacon, and P. Guest
Percutaneous image-guided biopsy of lung nodules in the assessment of disease activity in Wegener's granulomatosis
Rheumatology, July 1, 2000; 39(7): 776 - 782.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. E. Cox, C. Chiles, C. M. McManus, S. L. Aquino, and R. H. Choplin
Transthoracic Needle Aspiration Biopsy: Variables That Affect Risk of Pneumothorax
Radiology, July 1, 1999; 212(1): 165 - 168.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
R. S. Wong, L. Ketai, R. T. Temes, F. M. Follis, and R. Ashby
Air Embolus Complicating Transthoracic Percutaneous Needle Biopsy
Ann. Thorac. Surg., April 1, 1995; 59(4): 1010 - 1011.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1987 by the Radiological Society of North America.