|
|
||||||||
Radiology, Vol 165, 377-381, Copyright © 1987 by Radiological Society of North America
ARTICLES |
SO Pais, SE Mirvis and DF De Orchis
Department of Diagnostic Radiology, University of Maryland Medical System/Hospital, Baltimore 21201.
Kimray-Greenfield filters were inserted percutaneously into the inferior vena cava (IVC) in 57 patients. Thirty-six were placed from the right femoral vein, 14 from the left femoral vein, and seven from the right internal jugular vein. There were no deaths or major complications and only six minor complications. Inferior vena cavography was done before filter insertion in all cases. Cavography is vital to determine feasibility of filter insertion, route of insertion, and filter location; pertinent findings include caval size, presence or absence of clot in the IVC or iliac veins, and position of the renal veins. The guide wire provided with the standard filter introduction set has a tendency to catch on the filter as the wire is withdrawn. A stiff wire with a straight, tapered, floppy tip was substituted. The femoral approach is preferred when it is feasible. Though there was only one known occurrence of femoral vein thrombosis at the filter insertion site, other cases may have occurred and may not have been detected. If the frequency of this complication proves to be significant, the preferred route for filter insertion may have to be reconsidered.
This article has been cited by other articles:
![]() |
M. A. Savin, H. K. Panicker, S. Sadiq, Y. A. Albeer, and R. E. Olson Placement of Vena Cava Filters: Factors Affecting Technical Success and Immediate Complications Am. J. Roentgenol., September 1, 2002; 179(3): 597 - 602. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. H. White, H. Zhou, J. Kim, and P. S. Romano A Population-Based Study of the Effectiveness of Inferior Vena Cava Filter Use Among Patients With Venous Thromboembolism Arch Intern Med, July 10, 2000; 160(13): 2033 - 2041. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. J. Greenfield and M. C. Proctor Update on the Titanium Greenfield Filter and Recommendations for Insertion Perspectives in Vascular Surgery and Endovascular Therapy, January 1, 1998; 9(2): 41 - 46. [Abstract] [PDF] |
||||
![]() |
N. Nakagawa, A. H. Cragg, T. P. Smith, F. Castaneda, S. C. De Jong, and W. H. Barnhart Experimental Evaluation of a Retrievable Vena Cava Filter Vascular and Endovascular Surgery, January 1, 1994; 28(1): 7 - 14. [Abstract] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |