Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Brasch, R. C.
Right arrow Articles by Lipton, M. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Brasch, R. C.
Right arrow Articles by Lipton, M. J.

Radiology, Vol 165, 459-466, Copyright © 1987 by Radiological Society of North America


ARTICLES

Upper airway obstruction in infants and children: evaluation with ultrafast CT

RC Brasch, RG Gould, CA Gooding, HG Ringertz and MJ Lipton
Department of Radiology, University of California, San Francisco 94143.

The diagnostic accuracy of ultrafast computed tomography (CT) was evaluated prospectively in 25 infants and children with suspected airway obstruction. All examinations were conducted in spontaneously breathing, nonsedated children. Scan acquisition times were 0.05 or 0.1 second. CT examinations, completed in an average of 10 minutes, routinely included localizing, contiguous sections through the trachea followed by serial images obtained at a rate of 17 per second through regions of interest. Imaging results were correct in 24 of 25 examinations as judged from clinical and surgical data. Ultrafast CT data permitted diagnosis of dynamic changes in airway caliber, small intraluminal polyps, focal tracheal atresia, compressive mediastinal masses, and foreign body obstructions of the major bronchi. Dose measurements showed a maximum skin exposure of 245 mR (0.06 mC/kg) per 0.05-second image. Ultrafast CT provides an accurate, minimally invasive method for dynamic imaging of the airway in nonsedated children.


This article has been cited by other articles:


Home page
RadiologyHome page
R. H. Baroni, D. Feller-Kopman, M. Nishino, H. Hatabu, S. H. Loring, A. Ernst, and P. M. Boiselle
Tracheobronchomalacia: Comparison between End-expiratory and Dynamic Expiratory CT for Evaluation of Central Airway Collapse
Radiology, May 1, 2005; 235(2): 635 - 641.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
K. A. Carden, P. M. Boiselle, D. A. Waltz, and A. Ernst
Tracheomalacia and Tracheobronchomalacia in Children and Adults: An In-depth Review
Chest, March 1, 2005; 127(3): 984 - 1005.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
G. H. Mills, J. M. Wild, B. Eberle, and E. J. R. Van Beek
Functional magnetic resonance imaging of the lung
Br. J. Anaesth., July 1, 2003; 91(1): 16 - 30.
[Full Text] [PDF]


Home page
Arch Otolaryngol Head Neck SurgHome page
D. T. Rudman, C. A. Elmaraghy, W. E. Shiels, and G. J. Wiet
The Role of Airway Fluoroscopy in the Evaluation of Stridor in Children
Arch Otolaryngol Head Neck Surg, March 1, 2003; 129(3): 305 - 309.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1987 by the Radiological Society of North America.