Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bhasin, S.
Right arrow Articles by Resnick, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bhasin, S.
Right arrow Articles by Resnick, D.

Radiology, Vol 167, 145-149, Copyright © 1988 by Radiological Society of North America


ARTICLES

Three-dimensional quantitative CT of the proximal femur: relationship to vertebral trabecular bone density in postmenopausal women

S Bhasin, DJ Sartoris, L Fellingham, MB Zlatkin, M Andre and D Resnick
Department of Radiology, University of California Medical Center, San Diego 92103.

Dual-photon absorptiometry (DPA) of the proximal femur cannot independently measure cortical and high-turnover cancellous bone. In this investigation, integrated cancellous, cortical, and total bone densities in the femoral neck and intertrochanteric region were measured bilaterally in 22 women aged 42-75 years. Contiguous section data were analyzed with two different protocols by means of three- dimensional histogram software. Single-section quantitative computed tomography (CT) was used to determine mean mineral equivalent values for vertebral cancellous bone from T-11 to L-3 in each woman. Significant correlation was found between cancellous bone density at the two sites, as well as between total femoral and vertebral measurements. Femoral cortical bone density was predicted less well by means of the vertebral cancellous data. Cortical, cancellous, and total proximal femoral density values tended to exhibit bilateral symmetry. Quantitative three-dimensional volumetric CT affords comprehensive evaluation of proximal femoral mineral status because of its capability for selective measurement of cortical, cancellous, and total bone density.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1988 by the Radiological Society of North America.