Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Goodman, L. R.
Right arrow Articles by Wetherbee, J. N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Goodman, L. R.
Right arrow Articles by Wetherbee, J. N.

Radiology, Vol 170, 447-452, Copyright © 1989 by Radiological Society of North America


ARTICLES

Complications of automatic implantable cardioverter defibrillators: radiographic, CT, and echocardiographic evaluation

LR Goodman, GH Almassi, PJ Troup, JW Gurney, J Veseth-Rogers, PD Chapman and JN Wetherbee
Department of Radiology, Medical College of Wisconsin, Milwaukee 53226.

Automatic implantable cardioverter defibrillators (AICDs) were studied in three groups: (a) Serial radiographs were reviewed in 51 clinic patients. Twenty of 96 (21%) AICD patches distorted with time. (b) Thirty-six postoperative computed tomographic (CT) scans of asymptomatic patients revealed that pericardial fluid collections were frequent during the month after surgery but rare beyond that. Echocardiography was insensitive for these collections. CT also demonstrated dense fibrosis around some distorted patches, months after surgery. (c) Five other patients with pericardial infection had distorted patches, and the four studied with CT had fluid beneath their patches. (d) A case of constrictive pericarditis had distorted patches but was not diagnosed with CT. The authors conclude that distorted patches may indicate postoperative complications and that CT is the imaging modality of choice.


This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
L. E. Samuels, F. L. Samuels, M. S. Kaufman, R. J. Morris, and S. K. Brockman
Management of Infected Implantable Cardiac Defibrillators
Ann. Thorac. Surg., December 1, 1997; 64(6): 1702 - 1706.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
R. A. Bhadelia and E. Oates
Early Cardioverter Defibrillator Infection: Value of Indium-111 Leukocyte Imaging
Ann. Thorac. Surg., January 1, 1997; 63(1): 236 - 238.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
W. W. Barrington, U. Deligonul, A. R. Easley, and J. R. Windle
Defibrillator Patch Electrode Constriction: An Underrecognized Entity
Ann. Thorac. Surg., October 1, 1995; 60(4): 1112 - 1115.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
J. E. Molina, D. G. Benditt, and S. Adler
Crinkling of epicardial defibrillator patchesA common and serious problem
J. Thorac. Cardiovasc. Surg., July 1, 1995; 110(1): 258 - 264.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1989 by the Radiological Society of North America.