Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Haacke, E. M.
Right arrow Articles by Parrish, T. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Haacke, E. M.
Right arrow Articles by Parrish, T. B.

Radiology, Vol 170, 457-462, Copyright © 1989 by Radiological Society of North America


ARTICLES

Reduction of T2* dephasing in gradient field-echo imaging

EM Haacke, JA Tkach and TB Parrish
Department of Radiology, Case Western Reserve University, Cleveland, Ohio.

Fast gradient field-echo imaging is becoming more common in morphologic studies but is not as widespread as might be hoped because of its susceptibility to local field inhomogeneities that lead to spin dephasing (reducing T2 to T2*) and geometric distortion (frequency misregistration). These problems are manifested in both the in-plane and section-select directions. The authors show that reversal of many of these adverse effects is possible through the acquisition of the gradient field echo in a three- and four-dimensional mode for a fixed echo time (TE), since phase-encoding leads to the capture of the echo within the sampling window. This echo centering is shown to be equivalent to the reduction of dephasing across a pixel. Improvements are also obtained by reducing TE to as short a value as possible.


This article has been cited by other articles:


Home page
RadiologyHome page
L. M. White, J. K. Kim, M. Mehta, N. Merchant, M. E. Schweitzer, W. B. Morrison, C. R. Hutchison, and A. E. Gross
Complications of Total Hip Arthroplasty: MR Imaging-Initial Experience
Radiology, April 1, 2000; 215(1): 254 - 262.
[Abstract] [Full Text]


Home page
Am. J. Neuroradiol.Home page
J. S. Ross
Newer Sequences for Spinal MR Imaging: Smorgasbord or Succotash of Acronyms?
AJNR Am. J. Neuroradiol., March 1, 1999; 20(3): 361 - 373.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1989 by the Radiological Society of North America.