Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Varpula, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Varpula, M.

Radiology, Vol 172, 745-747, Copyright © 1989 by Radiological Society of North America


ARTICLES

Hysterosalpingography with a balloon catheter versus a cannula: evaluation of patient pain

M Varpula
Department of Diagnostic Radiology, University Central Hospital, Turku, Finland.

The amount of procedural and post-procedural pain due to hysterosalpingography performed with a standard cannula (28 patients) versus a balloon catheter (23 patients) was compared. Patients completed questionnaires in which they rated the pain they experienced during insertion of the instrument, during injection of contrast material, immediately after the examination, several hours after the examination, and over the next 6 days. The balloon catheter produced less discomfort during the procedure but significantly more discomfort after the procedure than did the standard cannula. These results indicate that hysterosalpingography with the balloon catheter is not as painless as has been claimed.


This article has been cited by other articles:


Home page
Hum ReprodHome page
G. Liberty, M. Gal, T. Halevy-Shalem, R. Michaelson-Cohen, N. Galoyan, J. Hyman, T. Eldar-Geva, E. Vatashsky, and E. Margalioth
Lidocaine-Prilocaine (EMLA) cream as analgesia for hysterosalpingography: a prospective, randomized, controlled, double blinded study
Hum. Reprod., May 1, 2007; 22(5): 1335 - 1339.
[Abstract] [Full Text] [PDF]


Home page
Obstet GynecolHome page
R. D. Robinson, Y. Casablanca, K. E. Pagano, N. A. Arthur, G. W. Bates, and A. M. Propst
Intracervical Block and Pain Perception During the Performance of a Hysterosalpingogram: A Randomized Controlled Trial
Obstet. Gynecol., January 1, 2007; 109(1): 89 - 93.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. F. L. de Mello Sr., M. S. Abrao, G. G. Cerri, and N. de Barros
Evaluation of pain in three hysterosalpingography techniques: metal cannula with and without paracervical blockage and balloon catheter.
Am. J. Roentgenol., July 1, 2006; 187(1): 86 - 89.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1989 by the Radiological Society of North America.