Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Berland, L. L.
Right arrow Articles by Keller, F. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Berland, L. L.
Right arrow Articles by Keller, F. S.

Radiology, Vol 174, 421-423, Copyright © 1990 by Radiological Society of North America


ARTICLES

Renal artery stenosis: prospective evaluation of diagnosis with color duplex US compared with angiography. Work in progress

LL Berland, DB Koslin, WD Routh and FS Keller
Department of Radiology, University of Alabama Hospital, Birmingham 35233.

A prospective, double-blind comparison of color duplex sonography with angiography was performed for diagnosing renal artery stenosis in 50 kidneys in 26 patients. The major criterion for diagnosing a diameter narrowing of more than 50% was a velocity of greater than 100 cm/sec. Angiography demonstrated 10 stenoses and one occlusion in main or accessory renal arteries in seven patients. Twenty-two percent of kidneys had accessory renal arteries. Color duplex scanning helped identify 58% of the main arteries and no accessory vessels. None of the stenotic vessels were identified with duplex scanning, but the single occluded vessel was correctly diagnosed. Nine of the 29 vessels identified with duplex scanning were incorrectly diagnosed as stenotic, findings yielding a specificity of 37%. The authors conclude that the published velocity threshold of 100 cm/sec is too low. Duplex scanning with current technology is unlikely to prove satisfactory for screening patients with hypertension for renal artery stenosis.


This article has been cited by other articles:


Home page
J Ultrasound MedHome page
S. K. Aytac, H. Yigit, T. Sancak, and H. Ozcan
Correlation Between the Diameter of the Main Renal Artery and the Presence of an Accessory Renal Artery: Sonographic and Angiographic Evaluation
J. Ultrasound Med., May 1, 2003; 22(5): 433 - 439.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. O. Bude, A. R. Forauer, E. M. Caoili, and H. V. Nghiem
Is It Necessary to Study Accessory Arteries When Screening the Renal Arteries for Renovascular Hypertension?
Radiology, February 1, 2003; 226(2): 411 - 416.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
H.-Y. Lee and E. G. Grant
Sonography in Renovascular Hypertension
J. Ultrasound Med., April 1, 2002; 21(4): 431 - 441.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. D. Qanadli, G. Soulez, E. Therasse, V. Nicolet, S. Turpin, D. Froment, M. Courteau, M.-C. Guertin, and V. L. Oliva
Detection of Renal Artery Stenosis: Prospective Comparison of Captopril-Enhanced Doppler Sonography, Captopril-Enhanced Scintigraphy, and MR Angiography
Am. J. Roentgenol., November 1, 2001; 177(5): 1123 - 1129.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
G. Soulez, V. L. Oliva, S. Turpin, R. Lambert, V. Nicolet, and E. Therasse
Imaging of Renovascular Hypertension: Respective Values of Renal Scintigraphy, Renal Doppler US, and MR Angiography
RadioGraphics, September 1, 2000; 20(5): 1355 - 1368.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Claudon, P. F. Plouin, G. M. Baxter, T. Rohban, and D. M. Devos
Renal Arteries in Patients at Risk of Renal Arterial Stenosis: Multicenter Evaluation of the Echo-enhancer SH U 508A at Color and Spectral Doppler US
Radiology, March 1, 2000; 214(3): 739 - 746.
[Abstract] [Full Text]


Home page
Am. J. Roentgenol.Home page
V. S. Lee, N. M. Rofsky, A. T. Ton, G. Johnson, G. A. Krinsky, and J. C. Weinreb
Angiotensin-Converting Enzyme Inhibitor-Enhanced Phase-Contrast MR Imaging to Measure Renal Artery Velocity Waveforms in Patients with Suspected Renovascular Hypertension
Am. J. Roentgenol., February 1, 2000; 174(2): 499 - 508.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
F. De Cobelli, M. Venturini, A. Vanzulli, S. Sironi, M. Salvioni, E. Angeli, P. Scifo, M. P. Garancini, R. Quartagno, G. Bianchi, et al.
Renal Arterial Stenosis: Prospective Comparison of Color Doppler US and Breath-hold, Three-dimensional, Dynamic, Gadolinium-enhanced MR Angiography
Radiology, February 1, 2000; 214(2): 373 - 380.
[Abstract] [Full Text]


Home page
RadiologyHome page
R. O. Bude, R. G. Larson, W. W. Nichols, and J. M. Rubin
Stenosis of the Main Artery Supplying an Organ: Effect of End-Organ Vascular Resistance on the Poststenotic Peak Systolic Velocity in an in Vitro Hydraulic Model at Doppler US
Radiology, July 1, 1999; 212(1): 79 - 87.
[Abstract] [Full Text]


Home page
Journal of Diagnostic Medical SonographyHome page
D. Grafe and S. Hanson
Sonographic Detection of Renal Artery Stenosis
Journal of Diagnostic Medical Sonography, March 1, 1995; 11(2): 67 - 74.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1990 by the Radiological Society of North America.