Radiology, Vol 175, 125-126, Copyright © 1990 by Radiological Society of North America
ARTICLES |
AJ Kuta and RM Benator
Department of Radiology, Medical College of Virginia, Richmond 23298- 0615.
The pressures generated by a barium suspension and various solutions of meglumine sodium diatrizoate in water were measured with a manometer. A pressure of 120 mm Hg was produced by a 3.5-foot (105-cm) column of 60% wt/vol barium and a 5-foot (150-cm) column of either a 1:3 or 1:4 solution of meglumine sodium diatrizoate and water. This is the pressure used to reduce an intussusception with air.
This article has been cited by other articles:
![]() |
G. del-Pozo, J. C. Albillos, D. Tejedor, R. Calero, M. Rasero, U. de-la-Calle, and U. Lopez-Pacheco Intussusception in Children: Current Concepts in Diagnosis and Enema Reduction RadioGraphics, March 1, 1999; 19(2): 299 - 319. [Abstract] [Full Text] [PDF] |
||||