Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Strecker, E. P.
Right arrow Articles by Schneider, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Strecker, E. P.
Right arrow Articles by Schneider, B.

Radiology, Vol 175, 97-102, Copyright © 1990 by Radiological Society of North America


ARTICLES

Expandable tubular stents for treatment of arterial occlusive diseases: experimental and clinical results. Work in progress

EP Strecker, D Liermann, KH Barth, HR Wolf, N Freudenberg, G Berg, M Westphal, P Tsikuras, M Savin and B Schneider
Department of Radiology, Diakonissenkrankenhaus Karlsruhe-Ruppurr, Federal Republic of Germany.

The balloon-expandable vascular prosthesis consists of a flexible, knitted tantalum wire mesh tube. To demonstrate its pliability, this prosthesis was tested experimentally in 10 mongrel dogs by implanting it into the proximal femoral arteries. The maximum follow-up time was 1 year. On the basis of the experimental results, in which there was no relevant stenosis, occlusion, or migration of the vascular prosthesis, nine patients were treated: one with iliac artery occlusive disease and eight with superficial femoral artery (SFA) occlusive disease (four reocclusions after angioplasty and four unsatisfactory primary angioplasty results). One SFA lesion was treated with the crossover method from the contralateral side. All implants remained patent without hemodynamically significant stenoses, with the longest observation time being 6 months. Flexible, expandable vascular prostheses are promising adjuncts to angioplasty.


This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
Y. Saito, K.-i. Minami, H. Kaneda, T. Okada, T. Maniwa, Y. Araki, H. Imamura, H. Yamada, K. Igaki, and H. Tamai
New Tubular Bioabsorbable Knitted Airway Stent: Feasibility Assessment for Delivery and Deployment in a Dog Model
Ann. Thorac. Surg., October 1, 2004; 78(4): 1438 - 1440.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
G. Geremia, T. Brack, L. Brennecke, M. Haklin, and R. Falter
Occlusion of Experimentally Created Fusiform Aneurysms with Porous Metallic Stents
AJNR Am. J. Neuroradiol., April 1, 2000; 21(4): 739 - 745.
[Abstract] [Full Text]


Home page
ChestHome page
C. T Bolliger, C. Wyser, X. Wu, R. Hauser, W. Studer, P. Dalquen, and A. P Perruchoud
Evaluation of a New Self-expandable Silicone Stent in an Experimental Tracheal Stenosis
Chest, February 1, 1999; 115(2): 496 - 501.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1990 by the Radiological Society of North America.