Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Katayama, H.
Right arrow Articles by Matsuura, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Katayama, H.
Right arrow Articles by Matsuura, K.

Radiology, Vol 175, 621-628, Copyright © 1990 by Radiological Society of North America


ARTICLES

Adverse reactions to ionic and nonionic contrast media. A report from the Japanese Committee on the Safety of Contrast Media

H Katayama, K Yamaguchi, T Kozuka, T Takashima, P Seez and K Matsuura
Japanese Committee on the Safety of Contrast Media, Juntendo University School of Medicine, Tokyo, Japan.

A large-scale (337,647 cases), nationwide comparative clinical study in Japan on adverse drug reactions (ADRs) to high-osmolar ionic contrast media and low-osmolar nonionic contrast media was performed prospectively. Ionic contrast media were administered in 169,284 cases (50.1%) and nonionic contrast media in 168,363 cases (49.9%). The overall prevalence of ADRs was 12.66% in the ionic contrast media group and 3.13% in the nonionic contrast media group. Severe ADRs occurred in 0.22% of the ionic and 0.04% of the nonionic contrast media examinations. One death occurred in each group, but a causal relationship to the contrast medium could not be established. It is concluded that nonionic contrast media significantly reduce the frequency of severe and potentially life-threatening ADRs to contrast media at all levels of risk and that use of these media represents the most effective means of increasing the safety of contrast media examinations.


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
C. L. Wang, R. H. Cohan, J. H. Ellis, E. M. Caoili, G. Wang, and I. R. Francis
Frequency, Outcome, and Appropriateness of Treatment of Nonionic Iodinated Contrast Media Reactions
Am. J. Roentgenol., August 1, 2008; 191(2): 409 - 415.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
R. W. Katzberg
"Acute Reactions to Urographic Contrast Medium: Incidence, Clinical Characteristics, and Relationship to History of Hypersensitivity States"--A Commentary
Am. J. Roentgenol., June 1, 2008; 190(6): 1431 - 1432.
[Full Text] [PDF]


Home page
JAMAHome page
C. A. Herzog
Incidence of Adverse Events Associated With Use of Perflutren Contrast Agents for Echocardiography
JAMA, May 7, 2008; 299(17): 2023 - 2025.
[Full Text] [PDF]


Home page
J Am Coll Cardiol ImgHome page
L. M. Boxt
CT Angiography in Children: It Is Accurate, But Is it Safe?
J. Am. Coll. Cardiol. Img., May 1, 2008; 1(3): 340 - 342.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. Trcka, C. Schmidt, C. S. Seitz, E.-B. Brocker, G. E. Gross, and A. Trautmann
Anaphylaxis to Iodinated Contrast Material: Nonallergic Hypersensitivity or IgE-Mediated Allergy?
Am. J. Roentgenol., March 1, 2008; 190(3): 666 - 670.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
W. C. Black, E. A. Krupinski, A. Relyea-Chew, and F. S. Chew
Methodology and Application of Clinical Trials in Radiology: Self-Assessment Module
Am. J. Roentgenol., March 1, 2008; 190(3_Supplement): S23 - S28.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
G. Bierry, F. Kellner, C. Barnig, P. K. Woodard, L. R. Goodman, J. G. Weg, and P. D. Stein
Management of Patients with History of Adverse Effects to Contrast Media When Pulmonary Artery CT Angiography Is Required
Radiology, December 1, 2007; 245(3): 919 - 921.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. R. Dillman, J. H. Ellis, R. H. Cohan, P. J. Strouse, and S. C. Jan
Frequency and Severity of Acute Allergic-Like Reactions to Gadolinium-Containing IV Contrast Media in Children and Adults
Am. J. Roentgenol., December 1, 2007; 189(6): 1533 - 1538.
[Abstract] [Full Text] [PDF]


Home page
Vasc MedHome page
C. M. Kramer, M. J. Budoff, Z. A. Fayad, V. A. Ferrari, C. Goldman, J. R. Lesser, E. T. Martin, S. Rajagopalan, J. P. Reilly, G. P. Rodgers, et al.
ACCF/AHA 2007 Clinical Competence Statement on vascular imaging with computed tomography and magnetic resonance
Vascular Medicine, November 1, 2007; 12(4): 359 - 378.
[PDF]


Home page
Br. J. Radiol.Home page
P S Sidhu, R Alikhan, T Ammar, and D J Quinlan
Lower limb contrast venography: a modified technique for use in thromboprophylaxis clinical trials for the accurate evaluation of deep vein thrombosis
Br. J. Radiol., November 1, 2007; 80(959): 859 - 865.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
Y. Yanaga, K. Awai, Y. Nakayama, T. Nakaura, Y. Tamura, M. Hatemura, and Y. Yamashita
Pancreas: Patient Body Weight tailored Contrast Material Injection Protocol versus Fixed Dose Protocol at Dynamic CT
Radiology, November 1, 2007; 245(2): 475 - 482.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
C. M. Kramer, M. J. Budoff, Z. A. Fayad, V. A. Ferrari, C. Goldman, J. R. Lesser, E. T. Martin, S. Rajagopalan, J. P. Reilly, G. P. Rodgers, et al.
ACCF/AHA 2007 Clinical Competence Statement on Vascular Imaging With Computed Tomography and Magnetic Resonance: A Report of the American College of Cardiology Foundation/American Heart Association/American College of Physicians Task Force on Clinical Competence and Training Developed in Collaboration With the Society of Atherosclerosis Imaging and Prevention, the Society for Cardiovascular Angiography and Interventions, the Society of Cardiovascular Computed Tomography, the Society for Cardiovascular Magnetic Resonance, and the Society for Vascular Medicine and Biology
J. Am. Coll. Cardiol., September 11, 2007; 50(11): 1097 - 1114.
[Full Text] [PDF]


Home page
Br. J. Radiol.Home page
M J Fernandez Cabezudo, G Petroianu, B Al-Ramadi, and R D Langer
Iosimenol, a new non-ionic dimeric contrast medium, does not induce immunoreactivity in the popliteal lymph node assay
Br. J. Radiol., September 1, 2007; 80(957): 713 - 718.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Kalinowski, K. Goldmann, M. Gotthardt, M. Rossler, A. Pfestroff, K. J. Klose, and H.-J. Wagner
Effectiveness and Renal Tolerance of Multidetector Helical CT with Gadobutrol: Results of a Comparative Porcine Study
Radiology, August 1, 2007; 244(2): 457 - 463.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. R. Dillman, P. J. Strouse, J. H. Ellis, R. H. Cohan, and S. C. Jan
Incidence and Severity of Acute Allergic-Like Reactions to IV Nonionic Iodinated Contrast Material in Children
Am. J. Roentgenol., June 1, 2007; 188(6): 1643 - 1647.
[Abstract] [Full Text] [PDF]


Home page
BMJHome page
P. Dawson
Adverse reactions to intravascular contrast agents.
BMJ, September 30, 2006; 333(7570): 663 - 664.
[Full Text] [PDF]


Home page
BMJHome page
M. R Tramer, E. von Elm, P. Loubeyre, and C. Hauser
Pharmacological prevention of serious anaphylactic reactions due to iodinated contrast media: systematic review
BMJ, September 30, 2006; 333(7570): 675.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. Utsunomiya, K. Awai, T. Sakamoto, T. Nishiharu, J. Urata, A. Taniguchi, T. Nakaura, and Y. Yamashita
Cardiac 16-MDCT for anatomic and functional analysis: assessment of a biphasic contrast injection protocol.
Am. J. Roentgenol., September 1, 2006; 187(3): 638 - 644.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
H. H. Schild, C. K. Kuhl, U. Hubner-Steiner, I. Bohm, and U. Speck
Adverse Events after Unenhanced and Monomeric and Dimeric Contrast-enhanced CT: A Prospective Randomized Controlled Trial
Radiology, July 1, 2006; 240(1): 56 - 64.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
Y. Safriel, M. Ali, M. Hayt, and R. Ang
Gadolinium Use in Spine Procedures for Patients with Allergy to Iodinated Contrast--Experience of 127 Procedures
AJNR Am. J. Neuroradiol., June 1, 2006; 27(6): 1194 - 1197.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. E. Zalis, J. J. Perumpillichira, C. Magee, G. Kohlberg, and P. F. Hahn
Tagging-based, Electronically Cleansed CT Colonography: Evaluation of Patient Comfort and Image Readability.
Radiology, April 1, 2006; 239(1): 149 - 159.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. K. Wysowski and P. Nourjah
Deaths attributed to x-ray contrast media on u.s. Death certificates.
Am. J. Roentgenol., March 1, 2006; 186(3): 613 - 615.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. Schroeder, A. Radtke, H. Kuehl, J. F. Debatin, M. Malago, and S. G. Ruehm
Evaluation of Living Liver Donors with an All-inclusive 3D Multi-Detector Row CT Protocol
Radiology, March 1, 2006; 238(3): 900 - 910.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. Utsunomiya, K. Awai, Y. Tamura, T. Nishiharu, J. Urata, T. Sakamoto, A. Taniguchi, and Y. Yamashita
16-MDCT Aortography with a Low-Dose Contrast Material Protocol
Am. J. Roentgenol., February 1, 2006; 186(2): 374 - 378.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
R. Ouwendijk, M. C. J. M. Kock, K. Visser, P. M. T. Pattynama, M. W. de Haan, and M. G. M. Hunink
Interobserver Agreement for the Interpretation of Contrast-Enhanced 3D MR Angiography and MDCT Angiography in Peripheral Arterial Disease
Am. J. Roentgenol., November 1, 2005; 185(5): 1261 - 1267.
[Abstract] [Full Text] [PDF]


Home page
Eur J EchocardiogrHome page
P.A. Dijkmans, C.A. Visser, and O. Kamp
Adverse reactions to ultrasound contrast agents: Is the risk worth the benefit?
Eur J Echocardiogr, October 1, 2005; 6(5): 363 - 366.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
S K Morcos
Acute serious and fatal reactions to contrast media: our current understanding
Br. J. Radiol., August 1, 2005; 78(932): 686 - 693.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Remy-Jardin, P. Dequiedt, O. Ertzbischoff, I. Tillie-Leblond, J. Bruzzi, A. Duhamel, and J. Remy
Safety and Effectiveness of Gadolinium-enhanced Multi-Detector Row Spiral CT Angiography of the Chest: Preliminary Results in 37 Patients with Contraindications to Iodinated Contrast Agents
Radiology, June 1, 2005; 235(3): 819 - 826.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
O. A. Meissner, J. Rieger, C. Weber, U. Siebert, B. Steckmeier, M. F. Reiser, and S. O. Schoenberg
Critical Limb Ischemia: Hybrid MR Angiography Compared with DSA
Radiology, April 1, 2005; 235(1): 308 - 318.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
P. V. Pandharipande, G. A. Krinsky, H. Rusinek, and V. S. Lee
Perfusion Imaging of the Liver: Current Challenges and Future Goals
Radiology, March 1, 2005; 234(3): 661 - 673.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. J. Mortele, M.-R. Oliva, S. Ondategui, P. R. Ros, and S. G. Silverman
Universal Use of Nonionic Iodinated Contrast Medium for CT: Evaluation of Safety in a Large Urban Teaching Hospital
Am. J. Roentgenol., January 1, 2005; 184(1): 31 - 34.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
M. A. Bettmann
Frequently Asked Questions: Iodinated Contrast Agents
RadioGraphics, October 1, 2004; 24(suppl_1): S3 - S10.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. Kaiser, T. Finnbogason, H. K. Jorulf, E. Soderman, and B. Frenckner
Suspected Appendicitis in Children: Diagnosis with Contrast-enhanced versus Nonenhanced Helical CT
Radiology, May 1, 2004; 231(2): 427 - 433.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K. Awai, K. Hiraishi, and S. Hori
Effect of Contrast Material Injection Duration and Rate on Aortic Peak Time and Peak Enhancement at Dynamic CT Involving Injection Protocol with Dose Tailored to Patient Weight
Radiology, January 1, 2004; 230(1): 142 - 150.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
H. S. Thomsen
Guidelines for Contrast Media from the European Society of Urogenital Radiology
Am. J. Roentgenol., December 1, 2003; 181(6): 1463 - 1471.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
A. Huber, J. Scheidler, B. Wintersperger, A. Baur, M. Schmidt, M. Requardt, N. Holzknecht, T. Helmberger, A. Billing, and M. Reiser
Moving-Table MR Angiography of the Peripheral Runoff Vessels: Comparison of Body Coil and Dedicated Phased Array Coil Systems
Am. J. Roentgenol., May 1, 2003; 180(5): 1365 - 1373.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
P. J. Dorio, F. T. Lee Jr., K. P. Henseler, M. Pilot, M. A. Pozniak, T. C. Winter III, and S. A. Shock
Using a Saline Chaser to Decrease Contrast Media in Abdominal CT
Am. J. Roentgenol., April 1, 2003; 180(4): 929 - 934.
[Abstract] [Full Text] [PDF]


Home page
NEJMHome page
C. M. Sandler
Contrast-Agent-Induced Acute Renal Dysfunction -- Is Iodixanol the Answer?
N. Engl. J. Med., February 6, 2003; 348(6): 551 - 553.
[Full Text] [PDF]


Home page
RadiologyHome page
A. Romano, M. C. Artesani, M. Andriolo, M. Viola, R. Pettinato, and A. Vecchioli-Scaldazza
Effective Prophylactic Protocol in Delayed Hypersensitivity to Contrast Media: Report of a Case Involving Lymphocyte Transformation Studies with Different Compounds
Radiology, November 1, 2002; 225(2): 466 - 470.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
P. Loubeyre, I. Debard, C. Nemoz, and V. A. T. Minh
High Opacification of Hilar Pulmonary Vessels with a Small Amount of Nonionic Contrast Medium for General Thoracic CT: A Prospective Study
Am. J. Roentgenol., June 1, 2002; 178(6): 1377 - 1381.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. Kaiser, B. Frenckner, and H. K. Jorulf
Suspected Appendicitis in Children: US and CT— A Prospective Randomized Study
Radiology, June 1, 2002; 223(3): 633 - 638.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
N. Fukuda, K. Shinohara, Y. Shimohakamada, S. T. Cochran, and K. Bomyea
Fatal Cardiac Arrest During Infusion of Nonionic ContrastMedia in a Patient with Essential Thrombocythemia
Am. J. Roentgenol., March 1, 2002; 178(3): 765 - 766.
[Full Text] [PDF]


Home page
Br. J. Radiol.Home page
N B Wright, H M L Carty, A Sprigg, V B Kampenes, M Friis, K K Petersen, G Stake, and A J Klaveness
Iodixanol in paediatric gastrointestinal imaging: safety and efficacy comparison with iohexol
Br. J. Radiol., February 1, 2002; 75(890): 127 - 135.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
D Violon
Stabilization of the hydrophilic sphere of non-ionic monomers: are all protected in a similar way?
Br. J. Radiol., December 1, 2001; 74(888): 1097 - 1102.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
B. H. Taragin and J. H. Newhouse
Answer
Am. J. Roentgenol., November 1, 2001; 177 (5): 1211 - 1212.
[Full Text] [PDF]


Home page
RadiologyHome page
T. F. Hany, T. J. Carroll, R. A. Omary, E. Esparza-Coss, F. R. Korosec, C. A. Mistretta, and T. M. Grist
Aorta and Runoff Vessels: Single-Injection MR Angiography with Automated Table Movement Compared with Multiinjection Time-resolved MR Angiography—Initial Results
Radiology, October 1, 2001; 221(1): 266 - 272.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
D. I. Paterson and K. Schwartzman
Strategies Incorporating Spiral CT for the Diagnosis of Acute Pulmonary Embolism : A Cost-effectiveness Analysis
Chest, June 1, 2001; 119(6): 1791 - 1800.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. T. Cochran, K. Bomyea, and J. W. Sayre
Trends in Adverse Events After IV Administration of Contrast Media
Am. J. Roentgenol., June 1, 2001; 176(6): 1385 - 1388.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. S. Freed, R. A. Leder, C. Alexander, D. M. DeLong, and M. A. Kliewer
Breakthrough Adverse Reactions to Low-Osmolar Contrast Media After Steroid Premedication
Am. J. Roentgenol., June 1, 2001; 176(6): 1389 - 1392.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
A. J. Megibow, G. Jacob, J. P. Heiken, E. K. Paulson, K. D. Hopper, G. Sica, S. Saini, B. A. Birnbaum, R. Redvanley, and E. K. Fishman
Quantitative and Qualitative Evaluation of Volume of Low Osmolality Contrast Medium Needed for Routine Helical Abdominal CT
Am. J. Roentgenol., March 1, 2001; 176(3): 583 - 589.
[Abstract] [Full Text] [PDF]


Home page
Postgrad. Med. J.Home page
Is spiral computed tomography the imaging modality of choice for renal colic?
Postgrad. Med. J., February 1, 2001; 77(904): 128d - 128.
[Full Text]


Home page
Arch Intern MedHome page
A. I. Neugut, A. T. Ghatak, and R. L. Miller
Anaphylaxis in the United States: An Investigation Into Its Epidemiology
Arch Intern Med, January 8, 2001; 161(1): 15 - 21.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
Y. M. Ruigrok, G. J. E. Rinkel, E. Buskens, B. K. Velthuis, and J. van Gijn
Perimesencephalic Hemorrhage and CT Angiography : A Decision Analysis
Stroke, December 1, 2000; 31(12): 2976 - 2983.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
A. N. Nicolaides
Investigation of Chronic Venous Insufficiency : A Consensus Statement
Circulation, November 14, 2000; 102 (20): e126 - e163.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
A. Huber, A. Heuck, A. Baur, T. Helmberger, T. Waggershauser, A. Billing, M. Heiss, R. Petsch, and M. Reiser
Dynamic Contrast-Enhanced MR Angiography from the Distal Aorta to the Ankle Joint with a Step-by-Step Technique
Am. J. Roentgenol., November 1, 2000; 175(5): 1291 - 1298.
[Abstract] [Full Text] [PDF]


Home page
J. Am. Soc. Nephrol.Home page
B. F. KING, J. E. REED, E. J. BERGSTRALH, P. F. SHEEDY II, and V. E. TORRES
Quantification and Longitudinal Trends of Kidney, Renal Cyst, and Renal Parenchyma Volumes in Autosomal Dominant Polycystic Kidney Disease
J. Am. Soc. Nephrol., August 1, 2000; 11(8): 1505 - 1511.
[Abstract] [Full Text]


Home page
RadiologyHome page
S. M. Goldman and C. M. Sandler
Genitourinary Imaging: The Past 40 Years
Radiology, May 1, 2000; 215(2): 313 - 324.
[Abstract] [Full Text]


Home page
Am. J. Roentgenol.Home page
P. Loubeyre, I. Debaro, C. Nemoz, and V. A. T. Minh
Using Thoracic Helical CT to Assess Iodine Concentration in a Small Volume of Nonionic Contrast Medium During Vascular Opacification: A Prospective Study
Am. J. Roentgenol., March 1, 2000; 174(3): 783 - 787.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
S. Wildermuth, M. Knauth, T. Brandt, R. Winter, K. Sartor, and W. Hacke
Role of CT Angiography in Patient Selection for Thrombolytic Therapy in Acute Hemispheric Stroke
Stroke, May 1, 1998; 29(5): 935 - 938.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
A. Culebras, C. S. Kase, J. C. Masdeu, A. J. Fox, R. N. Bryan, C. B. Grossman, D. H. Lee, H. P. Adams, W. Thies, and E. O. Members
Practice Guidelines for the Use of Imaging in Transient Ischemic Attacks and Acute Stroke : A Report of the Stroke Council, American Heart Association
Stroke, July 1, 1997; 28(7): 1480 - 1497.
[Full Text]


Home page
Journal of Health Politics, Policy and LawHome page
P. D. Jacobson and C. J. Rosenquist
The Use of Low-Osmolar Contrast Agents: Technological Change and Defensive Medicine
Journal of Health Politics Policy and Law, June 1, 1996; 21(2): 243 - 266.
[Abstract] [PDF]