Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Chen, C. C.
Right arrow Articles by Black, H. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Chen, C. C.
Right arrow Articles by Black, H. R.

Radiology, Vol 176, 365-370, Copyright © 1990 by Radiological Society of North America


ARTICLES

Patients at high risk for renal artery stenosis: a simple method of renal scintigraphic analysis with Tc-99m DTPA and captopril

CC Chen, PB Hoffer, G Vahjen, A Gottschalk, K Koster, IG Zubal, JF Setaro, DA Roer and HR Black
Department of Diagnostic Imaging, Yale University School of Medicine, New Haven, CT 06510.

Fifty patients with suspected renal artery stenosis (RAS) were studied with renal scintigraphy before and after administration of captopril. Twenty-three patients had RAS (greater than or equal to 75% RAS or greater than or equal to 50% RAS with poststenotic dilatation) and 27 had normal renal arteries at angiography. Angiotensin-converting enzyme inhibitors were discontinued 24 hours prior to renal scintigraphy; all other medications were continued. Each patient was evaluated with a simplified captopril renal scintigraphic protocol: renal imaging after administration of 12 mCi (444 MBq) of technetium-99m diethylenetriaminepentaacetic acid (DTPA), a 3-hour wait, oral administration of 50 mg of captopril, a 1-hour wait, and another scintigram obtained after administration of 12 mCi (444 MBq) of Tc-99m DTPA. Times of peak renal activity (Tmax) were determined from renal time-activity curves, and glomerular filtration rates (GFRs) were calculated with the Gates technique. A Tmax greater than or equal to 11 minutes after injection or a GFR ratio (larger GFR/smaller GFR) greater than 1.5 enabled detection of RAS with 91% sensitivity, 93% specificity, and 92% accuracy. Renal scintigraphy without captopril had only 43%-68% sensitivity in detecting RAS, depending on the criteria used.


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
S. D. Qanadli, G. Soulez, E. Therasse, V. Nicolet, S. Turpin, D. Froment, M. Courteau, M.-C. Guertin, and V. L. Oliva
Detection of Renal Artery Stenosis: Prospective Comparison of Captopril-Enhanced Doppler Sonography, Captopril-Enhanced Scintigraphy, and MR Angiography
Am. J. Roentgenol., November 1, 2001; 177(5): 1123 - 1129.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
D. J. Spinosa, A. H. Matsumoto, J. F. Angle, K. D. Hagspiel, J. K. McGraw, and C. Ayers
Renal Insufficiency: Usefulness of Gadodiamide-enhanced Renal Angiography to Supplement CO2-enhanced Renal Angiography for Diagnosis and Percutaneous Treatment
Radiology, March 1, 1999; 210(3): 663 - 672.
[Abstract] [Full Text]


Home page
RadiologyHome page
V. S. Lee, H. Rusinek, G. Johnson, N. M. Rofsky, G. A. Krinsky, and J. C. Weinreb
MR Renography with Low-Dose Gadopentetate Dimeglumine: Feasibility
Radiology, November 1, 2001; 221(2): 371 - 379.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1990 by the Radiological Society of North America.