Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Erlemann, R.
Right arrow Articles by Peters, P. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Erlemann, R.
Right arrow Articles by Peters, P. E.

Radiology, Vol 176, 489-495, Copyright © 1990 by Radiological Society of North America


ARTICLES

Musculoskeletal neoplasms: fast low-angle shot MR imaging with and without Gd-DTPA

R Erlemann, P Vassallo, G Bongartz, H Muller-Miny, E Rummeny, U Stober and PE Peters
Department of Clinical Radiology, Westfalische Wilhelms-Universitat, Munster, Federal Republic of Germany.

In 121 patients, image contrast and contrast-to-noise ratios (C/Ns) obtained with gadolinium diethylene-triaminepentaacetic acid (DTPA)- enhanced and nonenhanced fast low-angle shot (FLASH) sequences were compared with those achieved with spin-echo (SE) sequences. Among FLASH sequences, contrast between neoplasms and muscle was sufficient with a flip angle of 90 degrees following administration of Gd-DTPA but was 61% lower than that with the T2-weighted SE sequence. High contrast levels were obtained between tumors and bone marrow or fat in sclerotic, calcified, and fibrotic lesions with the use of a flip angle of 90 degrees and in lytic lesions with a flip angle of 10 degrees, reaching 66% of the contrast level obtained with the T1-weighted SE sequence. C/N between tumor and surrounding tissue was always significantly lower with FLASH sequences than with the ideal SE sequences usually used for tumor delineation. Thus, a replacement of the T2-weighted SE sequences by FLASH sequences cannot be recommended. A replacement of the T1-weighted SE sequences by FLASH sequences seems possible but does not significantly reduce examination time.


This article has been cited by other articles:


Home page
JBJSHome page
E. S. Malicky, J. L. Crary, M. J. Houghton, J. Agel, S. T. Hansen Jr., and B. J. Sangeorzan
Talocalcaneal and Subfibular Impingement in Symptomatic Flatfoot in Adults
J. Bone Joint Surg. Am., November 12, 2002; 84(11): 2005 - 2009.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. J. Siegel, H. Ishwaran, B. D. Fletcher, J. S. Meyer, F. A. Hoffer, D. Jaramillo, R. J. Hernandez, S. E. Roubal, B. A. Siegel, D. J. Caudry, et al.
Staging of Neuroblastoma at Imaging: Report of the Radiology Diagnostic Oncology Group
Radiology, April 1, 2002; 223(1): 168 - 175.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
A. J. Chien, J. A. Jacobson, W. Martel, M. U. Kabeto, and D. R. Marcantonio
Focal Radial Styloid Abnormality as a Manifestation of de Quervain Tenosynovitis
Am. J. Roentgenol., December 1, 2001; 177(6): 1383 - 1386.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1990 by the Radiological Society of North America.