Radiology, Vol 177, 35-38, Copyright © 1990 by Radiological Society of North America
ARTICLES |
Y Miki, M Matsuo, S Nishizawa, Y Kuroda, A Keyaki, Y Makita and J Kawamura
Department of Radiology, Tenri Hospital, Nara, Japan.
A dynamic study of magnetic resonance (MR) imaging was used to obtain successive heavily T1-weighted coronal images (spin-echo [SE] 100/15 [repetition time msec/echo time msec]) of normal pituitary glands and pituitary adenoma immediately after patients were given an intravenous bolus injection of gadopentetate dimeglumine. The images were obtained every minute for 5-8 minutes at 1.5 T. Usual T1-weighted images (SE 600/15) were also obtained before and after the dynamic study was performed. The study group consisted of 18 patients, 10 with normal pituitary glands, and eight with pituitary adenoma. Normal pituitary glands showed maximum enhancement on the first or second image following the administration of gadopentetate dimeglumine, followed by gradual signal reduction through the later images, whereas pituitary adenomas reached a peak of enhancement later and showed slower signal reduction than normal pituitaries. The difference of enhancement patterns between the normal pituitary gland and the pituitary adenoma produced prominent image contrast on the first or second image after administration of gadopentetate dimeglumine, which improved the visualization of one microadenoma and four normal pituitary glands that had been displaced by large adenomas. Dynamic MR imaging is a useful diagnostic procedure not only for detection of microadenomas, but also for visualization of pituitary glands that have been displaced by large pituitary adenomas.
This article has been cited by other articles:
![]() |
D. Batista, N. A. Courkoutsakis, E. H. Oldfield, K. J. Griffin, M. Keil, N. J. Patronas, and C. A. Stratakis Detection of Adrenocorticotropin-Secreting Pituitary Adenomas by Magnetic Resonance Imaging in Children and Adolescents with Cushing Disease J. Clin. Endocrinol. Metab., September 1, 2005; 90(9): 5134 - 5140. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. Imaoka, A. Wada, M. Matsuo, M. Yoshida, H. Kitagaki, and K. Sugimura MR Imaging of Disorders Associated with Female Infertility: Use in Diagnosis, Treatment, and Management RadioGraphics, November 1, 2003; 23(6): 1401 - 1421. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Shigematsu, Y. Korogi, M. Kitajima, A. Ishii, L. Liang, M. Yamura, K. Kawanaka, and M. Takahashi Abnormal Perfusion of the Pituitary Gland Secondary to Dural Arteriovenous Fistulas in the Cavernous Sinus: Dynamic MR Findings AJNR Am. J. Neuroradiol., May 1, 2003; 24(5): 930 - 936. [Abstract] [Full Text] [PDF] |
||||