Radiology, Vol 178, 175-179, Copyright © 1991 by Radiological Society of North America
ARTICLES |
H MacMahon, K Doi, S Sanada, SM Montner, ML Giger, CE Metz, N Nakamori, FF Yin, XW Xu and H Yonekawa
Kurt Rossmann Laboratories for Radiologic Image Research, Department of Radiology, University of Chicago, IL 60637.
High-resolution digital images make up very large data sets that are relatively slow to transmit and expensive to store. Data compression techniques are being developed to address this problem, but significant image deterioration can occur at high compression ratios. In this study, the authors evaluated a form of adaptive block cosine transform coding, a new compression technique that allows considerable compression of digital radiographs with minimal degradation of image quality. To determine the effect of data compression on diagnostic accuracy, observer tests were performed with 60 digitized chest radiographs (2,048 x 2,048 matrix, 1,024 shades of gray) containing subtle examples of pneumothorax, interstitial infiltrate, nodules, and bone lesions. Radiographs with no compression, with 25:1 compression, and with 50:1 compression ratios were presented in randomized order to 12 radiologists. The results suggest that, with this compression scheme, compression ratios as high as 25:1 may be acceptable for primary diagnosis in chest radiology.
This article has been cited by other articles:
![]() |
K. Sayinsu, F. Isik, G. Trakyali, and T. Arun An evaluation of the errors in cephalometric measurements on scanned cephalometric images and conventional tracings Eur J Orthod, February 1, 2007; 29(1): 105 - 108. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. M. Slone, E. Muka, and T. K. Pilgram Irreversible JPEG Compression of Digital Chest Radiographs for Primary Interpretation: Assessment of Visually Lossless Threshold Radiology, August 1, 2003; 228(2): 425 - 429. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. P. Ko, H. Rusinek, D. P. Naidich, G. McGuinness, A. N. Rubinowitz, B. S. Leitman, and J. M. Martino Wavelet Compression of Low-Dose Chest CT Data: Effect on Lung Nodule Detection Radiology, July 1, 2003; 228(1): 70 - 75. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Ohgiya, T. Gokan, H. Nobusawa, M. Hirose, N. Seino, H. Fujisawa, M. Baba, K. Nagai, K. Tanno, N. Takeyama, et al. Acute Cerebral Infarction: Effect of JPEG Compression on Detection at CT Radiology, April 1, 2003; 227(1): 124 - 127. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Kalyanpur, V. P. Neklesa, C. R. Taylor, A. R. Daftary, and J. A. Brink Evaluation of JPEG and Wavelet Compression of Body CT Images for Direct Digital Teleradiologic Transmission Radiology, December 1, 2000; 217(3): 772 - 779. [Abstract] [Full Text] |
||||
![]() |
W. F. Good, J. H. Sumkin, M. Ganott, L. Hardesty, B. Holbert, C. M. Johns, and A. H. Klym Detection of Masses and Clustered Microcalcifications on Data Compressed Mammograms: An Observer Performance Study Am. J. Roentgenol., December 1, 2000; 175(6): 1573 - 1576. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. M. Goo, J.-G. Im, J. H. Kim, J. B. Seo, T. S. Kim, S. J. Shine, and W. Lee Digital Chest Radiography with a Selenium-Based Flat-Panel Detector Versus a Storage Phosphor System: Comparison of Soft-Copy Images Am. J. Roentgenol., October 1, 2000; 175(4): 1013 - 1018. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. M. Slone, D. H. Foos, B. R. Whiting, E. Muka, D. A. Rubin, T. K. Pilgram, K. S. Kohm, S. S. Young, P. Ho, and D. D. Hendrickson Assessment of Visually Lossless Irreversible Image Compression: Comparison of Three Methods by Using an Image-Comparison Workstation Radiology, May 1, 2000; 215(2): 543 - 553. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |