|
|
||||||||
Radiology, Vol 180, 403-407, Copyright © 1991 by Radiological Society of North America
ARTICLES |
SH Parker, JD Lovin, WE Jobe, BJ Burke, KD Hopper and WF Yakes
Radiology Imaging Associates, Englewood, CO 80111.
One hundred two patients with mammographically suspicious, nonpalpable lesions underwent stereotactic breast biopsy with a biopsy gun and an automated 14-gauge cutting needle. After biopsy, a localization wire was placed and surgical biopsy performed. There was agreement of the histologic results from the gun biopsy and the surgical biopsy specimens in 98 cases (96%), including 22 of 23 carcinomas (96%) (kappa = 0.936). The gun biopsy yielded findings that led to the correct diagnosis in two cases involving lesions that were missed at surgical biopsy; two lesions found at surgery were missed at gun biopsy. The results of this study suggest that the use of 14-gauge needles improves agreement between surgical and needle core biopsy findings and that stereotactic biopsy with an automated needle and gun can be an acceptable alternative to surgical biopsy in women with mammographically suspicious breast lesions.
This article has been cited by other articles:
![]() |
M. J. Wagoner, C. Laronga, and G. Acs Extent and Histologic Pattern of Atypical Ductal Hyperplasia Present on Core Needle Biopsy Specimens of the Breast Can Predict Ductal Carcinoma In Situ in Subsequent Excision Am J Clin Pathol, January 1, 2009; 131(1): 112 - 121. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Schueller, S. Jaromi, L. Ponhold, M. Fuchsjaeger, M. Memarsadeghi, M. Rudas, M. Weber, L. Liberman, and T. H. Helbich US-guided 14-gauge Core-Needle Breast Biopsy: Results of a Validation Study in 1352 Cases Radiology, August 1, 2008; 248(2): 406 - 413. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. Sohn, Z. Arthurs, G. Herbert, J. Keylock, J. Perry, M. Eckert, D. Fellabaum, D. Smith, and T. Brown Atypical Ductal Hyperplasia: Improved Accuracy with the 11-Gauge Vacuum-Assisted versus the 14-Gauge Core Biopsy Needle Ann. Surg. Oncol., September 1, 2007; 14(9): 2497 - 2501. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J. Jackman and J. Rodriguez-Soto Breast microcalcifications: retrieval failure at prone stereotactic core and vacuum breast biopsy--frequency, causes, and outcome. Radiology, April 1, 2006; 239(1): 61 - 70. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. C. Riedl, G. Pfarl, M. Memarsadeghi, T. Wagner, F. Fitzal, M. Rudas, and T. H. Helbich Lesion Miss Rates and False-Negative Rates for 1115 Consecutive Cases of Stereotactically Guided Needle-localized Open Breast Biopsy with Long-term Follow-up Radiology, December 1, 2005; 237(3): 847 - 853. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. K. Koskela, M. Sudah, M. H. Berg, V. J. Karja, P. K. Mustonen, V. Kataja, and R. S. Vanninen Add-on Device for Stereotactic Core-Needle Breast Biopsy: How Many Biopsy Specimens Are Needed for a Reliable Diagnosis? Radiology, September 1, 2005; 236(3): 801 - 809. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Ghosh, L. J. Melton III, V. J. Suman, C. S. Grant, S. Sterioff, K. R. Brandt, C. Branch, T. A. Sellers, and L. C. Hartmann Breast Biopsy Utilization: A Population-Based Study Arch Intern Med, July 25, 2005; 165(14): 1593 - 1598. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. Doridot, M. Meunier, C. E. Khoury, C. Nos, A. Vincent-Salomon, B. Sigal-Zafrani, and K. B. Clough Stereotactic Radioguided Surgery by SiteSelect for Subclinical Mammographic Lesions Ann. Surg. Oncol., February 1, 2005; 12(2): 181 - 188. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. M. Lomoschitz, T. H. Helbich, M. Rudas, G. Pfarl, K. F. Linnau, A. Stadler, and R. J. Jackman Stereotactic 11-gauge Vacuum-assisted Breast Biopsy: Influence of Number of Specimens on Diagnostic Accuracy Radiology, September 1, 2004; 232(3): 897 - 903. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. M. Golub, C. L. Bennett, T. Stinson, L. Venta, and M. Morrow Cost Minimization Study of Image-Guided Core Biopsy Versus Surgical Excisional Biopsy for Women With Abnormal Mammograms J. Clin. Oncol., June 15, 2004; 22(12): 2430 - 2437. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. M. Hansen, X. Ye, B. J. Grube, and A. E. Giuliano Manipulation of the Primary Breast Tumor and the Incidence of Sentinel Node Metastases From Invasive Breast Cancer Arch Surg, June 1, 2004; 139(6): 634 - 640. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. J. Kirshenbaum, T. Voruganti, C. Overbeeke, M. D. Kirshenbaum, P. Patel, G. Kaplan, V. Maker, C. August, and R. P. Cavallino Stereotactic Core Needle Biopsy of Nonpalpable Breast Lesions Using a Conventional Mammography Unit with an Add-On Device Am. J. Roentgenol., August 1, 2003; 181(2): 527 - 531. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. J. Winchester, J. R. Bernstein, J. M. Jeske, M. H. Nicholson, E. A. Hahn, R. A. Goldschmidt, W. G. Watkin, S. F. Sener, M. B. Bilimoria, E. Barrera Jr, et al. Upstaging of Atypical Ductal Hyperplasia After Vacuum-Assisted 11-Gauge Stereotactic Core Needle Biopsy Arch Surg, June 1, 2003; 138(6): 619 - 623. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Pfarl, T. H. Helbich, C. C. Riedl, T. Wagner, M. Gnant, M. Rudas, and L. Liberman Stereotactic 11-Gauge Vacuum-Assisted Breast Biopsy: A Validation Study Am. J. Roentgenol., December 1, 2002; 179(6): 1503 - 1507. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. B. Mainiero, I. F. Gareen, C. E. Bird, W. Smith, C. Cobb, and B. Schepps Preferential Use of Sonographically Guided Biopsy to Minimize Patient Discomfort and Procedure Time in a Percutaneous Image-Guided Breast Biopsy Program J. Ultrasound Med., November 1, 2002; 21(11): 1221 - 1226. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Liberman, J. B. Kaplan, E. A. Morris, A. F. Abramson, J. H. Menell, and D. D. Dershaw To Excise or To Sample the Mammographic Target: What Is the Goal of Stereotactic II-Gauge Vacuum-Assisted Breast Biopsy? Am. J. Roentgenol., September 1, 2002; 179(3): 679 - 683. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Wunderbaldinger, G. Wolf, K. Turetschek, and T. H. Helbich Comparison of Sitting Versus Prone Position for Stereotactic Large-Core Breast Biopsy in Surgically Proven Lesions Am. J. Roentgenol., May 1, 2002; 178(5): 1221 - 1225. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Liberman and H. S. Cody III Percutaneous Biopsy and Sentinel Lymphadenectomy: Minimally Invasive Diagnosis and Treatment of Nonpalpable Breast Cancer Am. J. Roentgenol., October 1, 2001; 177(4): 887 - 891. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. N. Fahy, R. J. Bold, P. D. Schneider, V. Khatri, and J. E. Goodnight Jr Cost-Benefit Analysis of Biopsy Methods for Suspicious Mammographic Lesions Arch Surg, September 1, 2001; 136(9): 990 - 995. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. H. Parker, A. J. Klaus, P. J. Mc Wey, K. J. Schilling, T. E. Cupples, N. Duchesne, M. A. Guenin, and J. K. Harness Sonographically Guided Directional Vacuum-Assisted Breast Biopsy Using a Handheld Device Am. J. Roentgenol., August 1, 2001; 177(2): 405 - 408. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. G. Orel and M. D. Schnall MR Imaging of the Breast for the Detection, Diagnosis, and Staging of Breast Cancer Radiology, July 1, 2001; 220(1): 13 - 30. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Liberman, C. A. Gougoutas, M. F. Zakowski, L. R. LaTrenta, A. F. Abramson, E. A. Morris, and D. D. Dershaw Calcifications Highly Suggestive of Malignancy: Comparison of Breast Biopsy Methods Am. J. Roentgenol., July 1, 2001; 177(1): 165 - 172. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. D. Pisano, L. L. Fajardo, D. J. Caudry, N. Sneige, W. J. Frable, W. A. Berg, I. Tocino, S. J. Schnitt, J. L. Connolly, C. A. Gatsonis, et al. Fine-Needle Aspiration Biopsy of Nonpalpable Breast Lesions in a Multicenter Clinical Trial: Results from the Radiologic Diagnostic Oncology Group V Radiology, June 1, 2001; 219(3): 785 - 792. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Liberman, C. L. Benton, D. D. Dershaw, A. F. Abramson, L. R. LaTrenta, and E. A. Morris Learning Curve for Stereotactic Breast Biopsy: How Many Cases Are Enough? Am. J. Roentgenol., March 1, 2001; 176(3): 721 - 727. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J. Brenner, L. W. Bassett, L. L. Fajardo, D. D. Dershaw, W. P. Evans III, R. Hunt, C. Lee, I. Tocino, P. Fisher, M. McCombs, et al. Stereotactic Core-Needle Breast Biopsy: A Multi-institutional Prospective Trial Radiology, March 1, 2001; 218(3): 866 - 872. [Abstract] [Full Text] |
||||
![]() |
R. J. Brenner Percutaneous Removal of Postbiopsy Marking Clip in the Breast Using Stereotactic Technique Am. J. Roentgenol., February 1, 2001; 176(2): 417 - 419. [Full Text] [PDF] |
||||
![]() |
R. J. Jackman, F. Burbank, S. H. Parker, W. P. Evans III, M. C. Lechner, T. R. Richardson, A. A. Smid, H. B. Borofsky, C. H. Lee, H. M. Goldstein, et al. Stereotactic Breast Biopsy of Nonpalpable Lesions: Determinants of Ductal Carcinoma in Situ Underestimation Rates Radiology, February 1, 2001; 218(2): 497 - 502. [Abstract] [Full Text] |
||||
![]() |
D. J. Mullen, R. N. Eisen, R. D. Newman, P. M. Perrone, and J. C. Wilsey The Use of Carbon Marking after Stereotactic Large-Core-Needle Breast Biopsy Radiology, January 1, 2001; 218(1): 255 - 260. [Abstract] [Full Text] |
||||
![]() |
C. H. Lee, D. Carter, L. E. Philpotts, M. E. Couce, L. J. Horvath, R. C. Lange, and I. Tocino Ductal Carcinoma in Situ Diagnosed with Stereotactic Core Needle Biopsy: Can Invasion Be Predicted? Radiology, November 1, 2000; 217(2): 466 - 470. [Abstract] [Full Text] |
||||
![]() |
M. L. R. Darling, D. N. Smith, S. C. Lester, C. Kaelin, D.-L. G. Selland, C. M. Denison, P. J. DiPiro, D. I. Rose, E. Rhei, and J. E. Meyer Atypical Ductal Hyperplasia and Ductal Carcinoma In Situ as Revealed by Large-Core Needle Breast Biopsy: Results of Surgical Excision Am. J. Roentgenol., November 1, 2000; 175(5): 1341 - 1346. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Liberman, L. A. Ernberg, A. Heerdt, M. F. Zakowski, E. A. Morris, L. R. LaTrenta, A. F. Abramson, and D. D. Dershaw Palpable Breast Masses: Is There a Role for Percutaneous Imaging-Guided Core Biopsy? Am. J. Roentgenol., September 1, 2000; 175(3): 779 - 787. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Liberman and M. P. Sama Cost-Effectiveness of Stereotactic 11-Gauge Directional Vacuum-Assisted Breast Biopsy Am. J. Roentgenol., July 1, 2000; 175(1): 53 - 58. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. E. Burak Jr, K. E. Owens, M. B. Tighe, L. Kemp, S. A. Dinges, C. L. Hitchcock, and J. Olsen Vacuum-Assisted Stereotactic Breast Biopsy: Histologic Underestimation of Malignant Lesions Arch Surg, June 1, 2000; 135(6): 700 - 703. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Liberman Percutaneous Imaging-Guided Core Breast Biopsy: State of the Art at the Millennium Am. J. Roentgenol., May 1, 2000; 174(5): 1191 - 1199. [Full Text] [PDF] |
||||
![]() |
R. J. Brenner Lesions Entirely Removed during Stereotactic Biopsy: Preoperative Localization on the Basis of Mammographic Landmarks and Feasibility of Freehand Technique-Initial Experience Radiology, February 1, 2000; 214(2): 585 - 590. [Abstract] [Full Text] |
||||
![]() |
J. M. Hrung, C. P. Langlotz, S. G. Orel, K. R. Fox, M. D. Schnall, and J. S. Schwartz Cost-effectiveness of MR Imaging and Core-Needle Biopsy in the Preoperative Work-up of Suspicious Breast Lesions Radiology, October 1, 1999; 213(1): 39 - 49. [Abstract] [Full Text] |
||||
![]() |
J. E. Meyer, D. N. Smith, S. C. Lester, C. Kaelin, P. J. DiPiro, C. M. Denison, R. L. Christian, S. C. Harvey, D.-L. G. Selland, and S. M. Durfee Large-Core Needle Biopsy of Nonpalpable Breast Lesions JAMA, May 5, 1999; 281(17): 1638 - 1641. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. C. Harvey, C. M. Denison, S. C. Lester, P. J. DiPiro, D. N. Smith, and J. E. Meyer Fibrous Nodules Found at Large-Core Needle Biopsy of the Breast: Imaging Features Radiology, May 1, 1999; 211(2): 535 - 540. [Abstract] [Full Text] |
||||
![]() |
R. J. Jackman, K. W. Nowels, J. Rodriguez-Soto, F. A. Marzoni Jr, S. I. Finkelstein, and M. J. Shepard Stereotactic, Automated, Large-Core Needle Biopsy of Nonpalpable Breast Lesions: False-Negative and Histologic Underestimation Rates after Long-term Follow-up Radiology, March 1, 1999; 210(3): 799 - 805. [Abstract] [Full Text] |
||||
![]() |
H. Seoudi, J. Mortier, R. Basile, and E. Curletti Stereotactic Core Needle Biopsy of Nonpalpable Breast Lesions: Initial Experience With a Promising Technique Arch Surg, April 1, 1998; 133(4): 366 - 372. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Devia, K. A. Murray, and E. W. Nelson Stereotactic Core Needle Biopsy and the Workup of Mammographic Breast Lesions Arch Surg, May 1, 1997; 132(5): 512 - 516. [Abstract] [PDF] |
||||
![]() |
D. N. Smith, R. Christian, and J. E. Meyer Large-Core Needle Biopsy of Nonpalpable Breast Cancers: The Impact on Subsequent Surgical Excisions Arch Surg, March 1, 1997; 132(3): 256 - 259. [Abstract] [PDF] |
||||
![]() |
K. L. Kirklin, D. Thickman, and M. D. Smith Pseudoaneurysm: A Comnplication Secondary to Ultrasound-Guided Core Biopsy of the Breast Journal of Diagnostic Medical Sonography, September 1, 1996; 12(5): 220 - 223. [Abstract] [PDF] |
||||
![]() |
S. H. Parker, M. A. Dennis, A. T. Stavros, and K. K. Johnson Ultrasound-Guided Mamtmeotomoy: A New Breast Biopsy Technique Journal of Diagnostic Medical Sonography, May 1, 1996; 12(3): 113 - 118. [Abstract] [PDF] |
||||
![]() |
D. B. Kopans, K. K. Lindfors, L. P. Howell, D. Thickman, S. Parker, D. Clark, W. W. Logan-Young, N. Y. Hoffman, J. A. Janus, and W. L. Donegan Evaluation of a Breast Mass N. Engl. J. Med., March 18, 1993; 328(11): 810 - 812. [Full Text] |
||||
![]() |
R. J. Jackman and R. L. Lamm Stereotactic Histologic Biopsy in Breasts with Implants Radiology, January 1, 2002; 222(1): 157 - 164. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |