Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Long, A. L.
Right arrow Articles by Gaux, J. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Long, A. L.
Right arrow Articles by Gaux, J. C.

Radiology, Vol 180, 771-778, Copyright © 1991 by Radiological Society of North America


ARTICLES

Percutaneous iliac artery stent: angiographic long-term follow-up

AL Long, PE Page, AC Raynaud, BM Beyssen, JN Fiessinger, P Ducimetiere, JY Relland and JC Gaux
Cardiovascular Radiology Service, Hopital Broussais, Paris, France.

The authors conducted a prospective study of 49 consecutive patients with 53 lesions in 52 iliac arteries. All were treated between October 1987 and April 1990 with percutaneous transluminal angioplasty (PTA) and insertion of either a self-expandable or balloon-expandable stent. Lesions included total occlusion (28%), dissection (42%), post-PTA restenosis (21%), and unsatisfactory PTA (9%). Complications included one aortic protrusion, one acute thrombosis of the stent (resolved with urokinase), and three distal embolizations (5.7%) (resolved with urokinase and aspiration). During 15 months of follow-up, two patients died (one after occlusion). Three other occlusions occurred; one of these was resolved with local thrombolysis. Hyperplasia occurred in seven cases (13.5%), and stenosis occurred at the end of the stent because of incomplete covering of the lesion in three (5.8%); a complementary procedure was performed in six of these cases. Primary patency was 85.3% at 12 months and 80.9% at 18 months; secondary patency rate was 96.1% at 12 and at 18 months. At the end of the study, excluding data for the two patients who died, 27 limbs (54%) were asymptomatic and improvement was achieved in 19 (38%); the clinical success rate was 92%. No amputations were required.


This article has been cited by other articles:


Home page
VASC ENDOVASCULAR SURGHome page
S. Kalliafas, S. J. Travis, J. Macierewicz, S. W. Yusuf, S. C. Whitaker, I. Davidson, and B. R. Hopkinson
Color Duplex Ultrasonography of the Superior Mesenteric Artery After Placement of Endografts with Suprarenal Stents
Vascular and Endovascular Surgery, January 1, 2002; 36(1): 29 - 32.
[Abstract] [PDF]


Home page
J Am Coll CardiolHome page
Y.-f. Cheung, S. Sanatani, M. P. Leung, D. G. Human, A. K. T. Chau, and J. A. G. Culham
Early and intermediate-term complications of self-expanding stents limit its potential application in children with congenital heart disease
J. Am. Coll. Cardiol., March 15, 2000; 35(4): 1007 - 1015.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
P. R. Hilfiker, H. H. Quick, and J. F. Debatin
Plain and Covered Stent-Grafts: In Vitro Evaluation of Characteristics at Three-dimensional MR Angiography
Radiology, June 1, 1999; 211(3): 693 - 697.
[Abstract] [Full Text]


Home page
PERSPECT VASC SURG ENDOVASC THERHome page
G. J. Landry and J. M. Porter
Arterial Rupture Secondary to Placement of an Iliac Artery Stent
Perspectives in Vascular Surgery and Endovascular Therapy, January 1, 1995; 8(1): 69 - 75.
[PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1991 by the Radiological Society of North America.