Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wong, E. C.
Right arrow Articles by Hyde, J. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wong, E. C.
Right arrow Articles by Hyde, J. S.

Radiology, Vol 181, 393-397, Copyright © 1991 by Radiological Society of North America


ARTICLES

High-resolution, short echo time MR imaging of the fingers and wrist with a local gradient coil

EC Wong, A Jesmanowicz and JS Hyde
Department of Radiology, Medical College of Wisconsin, Milwaukee 53226.

The many fibrous tissues of the wrist and hand have short T2s, and, because of the small size of the tissues, their magnetic resonance (MR) imaging necessitates use of the high spatial resolution obtainable with fields of view as small as 2 cm x 2 cm x 1 mm. The authors demonstrate that the use of a local xyz gradient coil, positioned off-center in a clinical MR imager to facilitate patient positioning, permits acquisition of high-resolution images in spin-echo (SE) and gradient- recalled-echo (GRE) sequences with echo time (TE) as short as 6 msec (SE) or 3 msec (GRE). The authors compare this method for obtaining high-resolution images with the alternative method of using normal gradient strengths and increased pulse duration. The effects on image quality of TE, bandwidth, gradient strength, and chemical shift artifacts are presented. Images obtained with the local gradient coil of the carpal tunnel, carpal bones, and proximal interphalangeal joint in healthy volunteers are shown.


This article has been cited by other articles:


Home page
Ann Rheum DisHome page
I. Eshed, M. Bollow, D. G McGonagle, A. L. Tan, C. E Althoff, P. Asbach, and K.-G. A Hermann
MRI of enthesitis of the appendicular skeleton in spondyloarthritis
Ann Rheum Dis, December 1, 2007; 66(12): 1553 - 1559.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
N. Saupe, K. P. Prussmann, R. Luechinger, P. Bosiger, B. Marincek, and D. Weishaupt
MR Imaging of the Wrist: Comparison between 1.5- and 3-T MR Imaging--Preliminary Experience
Radiology, January 1, 2005; 234(1): 256 - 264.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. Kocharian, M. C. Adkins, K. K. Amrami, K. P. McGee, P. A. Rouleau, D. E. Wenger, R. L. Ehman, and J. P. Felmlee
Wrist: Improved MR Imaging with Optimized Transmit-Receive Coil Design
Radiology, June 1, 2002; 223(3): 870 - 876.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
C. Muhle, L. R. Frank, T. Rand, L. Yeh, E. C. Wong, A. Skaf, R. W. M. Dantas, P. Haghighi, D. Trudell, and D. Resnick
Collateral Ligaments of the Ankle: High-Resolution MR Imaging with a Local Gradient Coil and Anatomic Correlation in Cadavers
RadioGraphics, May 1, 1999; 19(3): 673 - 683.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
L. R. Frank, E. C. Wong, W.-M. Luh, J. M. Ahn, and D. Resnick
Articular Cartilage in the Knee: Mapping of the Physiologic Parameters at MR Imaging with a Local Gradient Coil—Preliminary Results
Radiology, January 1, 1999; 210(1): 241 - 246.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1991 by the Radiological Society of North America.