|
|
||||||||
Radiology, Vol 181, 689-691, Copyright © 1991 by Radiological Society of North America
ARTICLES |
G Marmolya, EJ Wiesen, R Yagan, CD Haria and AC Shah
Department of Radiology, Case Western Reserve University, Cleveland, OH.
While computed tomography (CT) has become an important imaging modality in the evaluation of the paranasal sinuses, the radiation dose remains higher than is necessary. With use of a head phantom and constant kilovolt peak setting, axial and coronal CT scans of the paranasal sinuses were obtained at each of six successively lower milliampere second settings than are commonly used in clinical practice. Although noise, as measured by the standard deviation of the CT numbers, did increase, images were of diagnostic quality even when dose levels were reduced by a factor of 28. In the same incremental manner, the milliampere second settings used in scanning 90 patients were reduced, with no loss of diagnostic quality. The authors discuss the methods of analysis and the advantages of use of lower milliampere second settings at CT scanning of the sinuses.
This article has been cited by other articles:
![]() |
R Olszewski, H Reychler, G Cosnard, J M Denis, S Vynckier, and F Zech Accuracy of three-dimensional (3D) craniofacial cephalometric landmarks on a low-dose 3D computed tomograph Dentomaxillofac. Radiol., July 1, 2008; 37(5): 261 - 267. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. H. Brem, A. A. Zamani, R. Riva, K. H. Zou, Z. Rumboldt, F. F. Hennig, R. Kikinis, A. M. Norbash, and U. J. Schoepf Multidetector CT of the Paranasal Sinus: Potential for Radiation Dose Reduction Radiology, June 1, 2007; 243(3): 847 - 852. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. H. Mulkens, C. Broers, S. Fieuws, J.-L. Termote, and P. Bellnick Comparison of Effective Doses for Low-Dose MDCT and Radiographic Examination of Sinuses in Children Am. J. Roentgenol., May 1, 2005; 184(5): 1611 - 1618. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. J. Fox Use of the Lowest Necessary Radiation Dose AJNR Am. J. Neuroradiol., April 1, 2004; 25(4): 519 - 519. [Full Text] [PDF] |
||||
![]() |
M. K. Kalra, M. M. Maher, T. L. Toth, L. M. Hamberg, M. A. Blake, J.-A. Shepard, and S. Saini Strategies for CT Radiation Dose Optimization Radiology, March 1, 2004; 230(3): 619 - 628. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Tack, J. Widelec, V. De Maertelaer, J.-M. Bailly, C. Delcour, and P. A. Gevenois Comparison Between Low-Dose and Standard-Dose Multidetector CT in Patients with Suspected Chronic Sinusitis Am. J. Roentgenol., October 1, 2003; 181(4): 939 - 944. [Abstract] [Full Text] [PDF] |
||||
![]() |
I Zammit-Maempel, C L Chadwick, and S P Willis Radiation dose to the lens of eye and thyroid gland in paranasal sinus multislice CT Br. J. Radiol., June 1, 2003; 76(906): 418 - 420. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Aalokken, T Hagtvedt, I Dalen, and A Kolbenstvedt Conventional sinus radiography compared with CT in the diagnosis of acute sinusitis Dentomaxillofac. Radiol., January 1, 2003; 32(1): 60 - 62. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. K. Kalra, S. Prasad, S. Saini, M. A. Blake, J. Varghese, E. F. Halpern, J. T. Rhea, and J. H. Thrall Clinical Comparison of Standard-Dose and 50% Reduced--Dose Abdominal CT: Effect on Image Quality Am. J. Roentgenol., November 1, 2002; 179(5): 1101 - 1106. [Abstract] [Full Text] [PDF] |
||||
![]() |
S A Sohaib, P D Peppercorn, J A Horrocks, M H Keene, G S Kenyon, and R H Reznek The effect of decreasing mAs on image quality and patient dose in sinus CT Br. J. Radiol., February 1, 2001; 74(878): 157 - 161. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. Huda, E. M. Scalzetti, and G. Levin Technique Factors and Image Quality as Functions of Patient Weight at Abdominal CT Radiology, November 1, 2000; 217(2): 430 - 435. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |