Radiology, Vol 182, 35-40, Copyright © 1992 by Radiological Society of North America
ARTICLES |
JF Polak, RL Bajakian, DH O'Leary, MR Anderson, MC Donaldson and FA Jolesz
Department of Radiology, Brigham and Women's Hospital, Boston, MA 02115.
Findings of two-dimensional time-of-flight magnetic resonance (MR) angiography projection angiograms were prospectively compared with those of color Doppler sonography by using angiography as a standard in 23 consecutive patients (42 carotid bifurcations) to evaluate their utility in determining the presence of carotid artery stenosis. MR angiography helped detect 50% or greater lumen diameter stenosis (sensitivity, 0.96; specificity, 0.64). Color Doppler sonography with 1.25 m/sec peak systolic velocity as a threshold had a sensitivity of 0.96 and a specificity of 0.71. Statistical analysis showed a correlation between percentage of lumen diameter narrowing and the length of the zone of signal intensity loss with MR angiography (r = .69; P less than .0001). A stronger relationship was obtained between angiographic narrowing and peak systolic velocity derived from color Doppler sonography (r = .80; P less than .0001). Two-dimensional time- of-flight MR angiography displayed as projection angiograms and combined with carotid artery and combined with carotid artery sonography is a useful approach for helping detect and potentially grade the severity of stenoses of the carotid artery.
This article has been cited by other articles:
![]() |
E. M. Groves, W. Bireley, K. Dill, T. J. Carroll, and J. C. Carr Quantitative Analysis of ECG-Gated High-Resolution Contrast-Enhanced MR Angiography of the Thoracic Aorta Am. J. Roentgenol., February 1, 2007; 188(2): 522 - 528. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. W. Yang, J. C. Carr, S. F. Futterer, M. D. Morasch, B. P. Yang, S. M. Shors, and J. P. Finn Contrast-Enhanced MR Angiography of the Carotid and Vertebrobasilar Circulations AJNR Am. J. Neuroradiol., September 1, 2005; 26(8): 2095 - 2101. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Wessels, J. U. Harrer, S. Stetter, M. Mull, and C. Klotzsch Three-Dimensional Assessment of Extracranial Doppler Sonography in Carotid Artery Stenosis Compared With Digital Subtraction Angiography Stroke, August 1, 2004; 35(8): 1847 - 1851. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. H. Lev, J. M. Romero, D. N.F. Goodman, R. Bagga, H. Y. K. Kim, N. A. Clerk, R. H. Ackerman, and R. G. Gonzalez Total Occlusion versus Hairline Residual Lumen of the Internal Carotid Arteries: Accuracy of Single Section Helical CT Angiography AJNR Am. J. Neuroradiol., June 1, 2003; 24(6): 1123 - 1129. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. C. Carr, J. Ma, V. Desphande, S. Pereles, G. Laub, and J. P. Finn High-Resolution Breath-Hold Contrast-Enhanced MR Angiography of the Entire Carotid Circulation Am. J. Roentgenol., March 1, 2002; 178(3): 543 - 549. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. E Westwood, S. Kelly, E. Berry, J. M Bamford, M. J Gough, C M. Airey, J. F M Meaney, L. M Davies, J. Cullingworth, and M. A Smith Use of magnetic resonance angiography to select candidates with recently symptomatic carotid stenosis for surgery: systematic review BMJ, January 26, 2002; 324(7331): 198 - 198. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. A. Staroselskaya, C. Chaves, B. Silver, I. Linfante, R. R. Edelman, L. Caplan, S. Warach, and A. E. Baird Relationship Between Magnetic Resonance Arterial Patency and Perfusion-Diffusion Mismatch in Acute Ischemic Stroke and Its Potential Clinical Use Arch Neurol, July 1, 2001; 58(7): 1069 - 1074. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. M. Serfaty, P. Chirossel, J. M. Chevallier, R. Ecochard, J. C. Froment, and P. C. Douek Accuracy of Three-Dimensional Gadolinium-Enhanced MR Angiography in the Assessment of Extracranial Carotid Artery Disease Am. J. Roentgenol., August 1, 2000; 175(2): 455 - 463. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. D. Marcus, V. J. Ladam-Marcus, J.-L. Bigot, C. Clement, B. Baehrel, and B. P. Menanteau Carotid Arterial Stenosis: Evaluation at CT Angiography with the Volume-rendering Technique Radiology, June 1, 1999; 211(3): 775 - 780. [Abstract] [Full Text] |
||||
![]() |
X. Leclerc, O. Godefroy, C. Lucas, J.-F. Benhaim, T. S. Michel, D. Leys, and J. P. Pruvo Internal Carotid Arterial Stenosis: CT Angiography with Volume Rendering Radiology, March 1, 1999; 210(3): 673 - 682. [Abstract] [Full Text] |
||||
![]() |
M. R. Patel, K. M. Kuntz, R. A. Klufas, D. Kim, J. Kramer, J. F. Polak, J. J. Skillman, A. D. Whittemore, R. R. Edelman, and K. C. Kent Preoperative Assessment of the Carotid Bifurcation : Can Magnetic Resonance Angiography and Duplex Ultrasonography Replace Contrast Arteriography? Stroke, October 1, 1995; 26(10): 1753 - 1758. [Abstract] [Full Text] |
||||
![]() |
J. F. Reed III, S. McCullough, and T. Wasser Magnetic Resonance Angiography and Duplex Scanning Concordance in Detecting Severe Carotid Stenosis: A Methodological Review Vascular and Endovascular Surgery, May 1, 1995; 29(3): 177 - 183. [Abstract] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |