Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by van Rossum, A. C.
Right arrow Articles by Valk, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by van Rossum, A. C.
Right arrow Articles by Valk, J.

Radiology, Vol 182, 685-691, Copyright © 1992 by Radiological Society of North America


ARTICLES

Global left ventricular perfusion: noninvasive measurement with cine MR imaging and phase velocity mapping of coronary venous outflow

AC van Rossum, FC Visser, MB Hofman, MA Galjee, N Westerhof and J Valk
Department of Cardiology, Free University Hospital Amsterdam, The Netherlands.

Velocity and volumetric flow of left ventricular venous outflow in the distal coronary sinus were measured with magnetic resonance (MR) velocity mapping techniques in 24 healthy men. A total of 16-21 velocity maps were acquired throughout the cardiac cycle. To determine the accuracy of the MR velocity-mapping pulse sequence, measurements were obtained with a flow phantom. Mean blood flow was 144 mL/min +/- 62 (standard deviation); mean velocity, 2.1 cm/sec +/- 1.0; and mean cross-sectional area, 1.2 cm2. Phasic measurements revealed a biphasic flow pattern in the coronary sinus, with a first peak in systole (257 mL/min +/- 174) and a second peak in early diastole (1,090 mL/min +/- 487). The cross-sectional area varied between 0.5 cm2 +/- 0.2 at end diastole and 1.9 cm2 +/- 0.6 in systole, a finding that suggests a capacitance function for venous outflow. Mean blood flow measurements were in agreement with measurements obtained invasively in previous studies. It is concluded that MR velocity mapping can enable noninvasive measurement of coronary venous outflow and global left ventricular perfusion and may become clinically useful in assessment of coronary blood flow reserve.


This article has been cited by other articles:


Home page
RadiologyHome page
G. K. Lund, M. F. Wendland, A. Shimakawa, H. Arheden, F. Ståhlberg, C. B. Higgins, and M. Saeed
Coronary Sinus Flow Measurement by Means of Velocity-encoded Cine MR Imaging: Validation by Using Flow Probes in Dogs
Radiology, November 1, 2000; 217(2): 487 - 493.
[Abstract] [Full Text]


Home page
Am. J. Neuroradiol.Home page
N. Hirabuki, Y. Watanabe, T. Mano, N. Fujita, H. Tanaka, T. Ueguchi, and H. Nakamura
Quantitation of Flow in the Superior Sagittal Sinus Performed with Cine Phase-contrast MR Imaging of Healthy and Achondroplastic Children
AJNR Am. J. Neuroradiol., August 1, 2000; 21(8): 1497 - 1501.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1992 by the Radiological Society of North America.