|
|
||||||||
Radiology, Vol 183, 151-154, Copyright © 1992 by Radiological Society of North America
ARTICLES |
D Pavcnik, KC Wright and S Wallace
Department of Diagnostic Radiology, University of Texas M. D. Anderson Cancer Center, Houston 77030.
A prosthetic caged-ball aortic valve that can be placed with transcatheter techniques was designed, constructed, and initially evaluated in 12 adult mongrel dogs. The prosthesis consisted of a ring, cage, and ball. The ring was made of stainless steel wire coiled in a springlike configuration and covered with an expandable nylon mesh. The cage consisted of a self-expanding Gianturco stent with flat stainless steel wires attached across the cranial end. The ball was a detachable latex balloon filled with a radiopaque silicone prepolymer system. The self-expanding valve was easily passed through an 11- or 12-F Teflon sheath and was placed in the ascending aorta by means of the carotid approach. The stability and efficacy of the prosthesis were evaluated radiographically for as long as the valve remained functional (1-3 hours). The competency of the valve and the patency of the coronary arteries were determined angiographically over the same period. The results of these studies indicate that development and transcatheter placement of a prosthetic aortic valve are feasible.
This article has been cited by other articles:
![]() |
R. Quaden, T. Attmann, M. Schunke, D. Theisen-Kunde, J. Cremer, and G. Lutter Percutaneous aortic valve replacement: Endovascular resection of human aortic valves in situ. J. Thorac. Cardiovasc. Surg., May 1, 2008; 135(5): 1081 - 1086. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Feldman and M. B. Leon Prospects for Percutaneous Valve Therapies Circulation, December 11, 2007; 116(24): 2866 - 2877. [Full Text] [PDF] |
||||
![]() |
F. Beyersdorf Transapical transcatheter aortic valve implantation Eur. J. Cardiothorac. Surg., January 1, 2007; 31(1): 7 - 8. [Full Text] [PDF] |
||||
![]() |
S. V. Lichtenstein Closed heart surgery: Back to the future J. Thorac. Cardiovasc. Surg., May 1, 2006; 131(5): 941 - 943. [Full Text] [PDF] |
||||
![]() |
C. H. Huber and L. K. von Segesser Direct Access Valve Replacement (DAVR) -- are we entering a new era in cardiac surgery? Eur. J. Cardiothorac. Surg., March 1, 2006; 29(3): 380 - 385. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Lutter, R. Ardehali, J. Cremer, and P. Bonhoeffer Percutaneous Valve Replacement: Current State and Future Prospects Ann. Thorac. Surg., December 1, 2004; 78(6): 2199 - 2206. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. D. Fish Percutaneous Heart Valve Replacement: Enthusiasm Tempered Circulation, October 5, 2004; 110(14): 1876 - 1878. [Full Text] [PDF] |
||||
![]() |
A. F. Corno, J. Zhou, P. Tozzi, and L. K. von Segesser Off-bypass implantation of a self-expandable valved stent between inferior vena cava and right atrium Interactive CardioVascular and Thoracic Surgery, June 1, 2003; 2(2): 166 - 169. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Lutter, D. Kuklinski, G. Berg, P. von Samson, J. Martin, M. Handke, P. Uhrmeister, and F. Beyersdorf Percutaneous aortic valve replacement: An experimental study. I. Studies on implantation J. Thorac. Cardiovasc. Surg., April 1, 2002; 123(4): 768 - 776. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. C. Ashton Jr., D. J. Goldstein, D. D'Alessandro, A. D. Weinberg, D. Burkhoff, H. D. Rosskothen, G. M. Lemole, and M. C. Oz DEVELOPMENT OF AN INTRALUMINAL DEVICE FOR THE TREATMENT OF AORTIC REGURGITATION: PROTOTYPE AND IN VITRO TESTING SYSTEM J. Thorac. Cardiovasc. Surg., October 1, 1996; 112(4): 979 - 983. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |