Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Dobbins, J. T.
Right arrow Articles by Ravin, C. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Dobbins, J. T., 3d
Right arrow Articles by Ravin, C. E.

Radiology, Vol 183, 179-187, Copyright © 1992 by Radiological Society of North America


ARTICLES

Threshold perception performance with computed and screen-film radiography: implications for chest radiography

JT Dobbins 3d, JJ Rice, CA Beam and CE Ravin
Department of Radiology, Duke University Medical Center, Durham, NC 27710.

Images of a phantom obtained with computed radiography and standard screen-film imaging were compared to evaluate observer threshold perception performance with a modified contrast-detail technique. Optimum exposure necessary for performance with the imaging plate technique to match that with screen-film techniques was determined, as was comparative performance with variation in kilovoltages, plate type, spatial enhancement, and hard-copy interpolation method. It was found that computed radiography necessitates about 75%-100% more exposure than screen-film radiography to optimally match performance with Ortho- C film with Lanex regular or medium screens (Eastman Kodak, Rochester, NY) for detection of objects 0.05-2.0 cm in diameter. However, only minimal loss of detection performance (approximately 10% overall) was experienced if standard screen-film exposures were used with computed radiography. Little change in observer performance was found with variation in plate type, spatial enhancement, or method of hard-copy interpolation. However, perception performance with computed radiographic images was better at lower kilovoltages.


This article has been cited by other articles:


Home page
Br. J. Radiol.Home page
C S MOORE, A W BEAVIS, and J R SAUNDERSON
Investigation of optimum X-ray beam tube voltage and filtration for chest radiography with a computed radiography system
Br. J. Radiol., October 1, 2008; 81(970): 771 - 777.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
C S Moore, G P Liney, A W Beavis, and J R Saunderson
A method to optimize the processing algorithm of a computed radiography system for chest radiography
Br. J. Radiol., September 1, 2007; 80(957): 724 - 730.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
S. Mazzocchi, G. Belli, S. Busoni, C. Gori, I. Menchi, P. Salucci, A. Taddeucci, and G. Zatelli
AEC set-up optimisation with computed radiography imaging
Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 169 - 173.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. J. M. Kroft, W. J. H. Veldkamp, B. J. A. Mertens, M. V. Boot, and J. Geleijns
Comparison of Eight Different Digital Chest Radiography Systems: Variation in Detection of Simulated Chest Disease
Am. J. Roentgenol., August 1, 2005; 185(2): 339 - 346.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
A. Tingberg and D. Sjostrom
Optimisation of image plate radiography with respect to tube voltage
Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 286 - 293.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
I D Honey, A Mackenzie, and D S Evans
Investigation of optimum energies for chest imaging using film-screen and computed radiography
Br. J. Radiol., May 1, 2005; 78(929): 422 - 427.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
E. Eisenhuber, A. Stadler, M. Prokop, M. Fuchsjager, M. Weber, and C. Schaefer-Prokop
Detection of Monitoring Materials on Bedside Chest Radiographs with the Most Recent Generation of Storage Phosphor Plates: Dose Increase Does Not Improve Detection Performance
Radiology, April 1, 2003; 227(1): 216 - 221.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. P. Frush, L. F. Donnelly, and H. G. Chotas
Contemporary Pediatric Thoracic Imaging
Am. J. Roentgenol., September 1, 2000; 175(3): 841 - 851.
[Full Text] [PDF]


Home page
RadiologyHome page
R. V. Kaczmarek, B. J. Conway, R. O. Slayton, and O. H. Suleiman
Results of a Nationwide Survey of Chest Radiography: Comparison with Results of a Previous Study
Radiology, June 1, 2000; 215(3): 891 - 896.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1992 by the Radiological Society of North America.