Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Foo, T. K.
Right arrow Articles by Slayman, B. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Foo, T. K.
Right arrow Articles by Slayman, B. E.

Radiology, Vol 183, 473-477, Copyright © 1992 by Radiological Society of North America


ARTICLES

Pulmonary vasculature: single breath-hold MR imaging with phased-array coils

TK Foo, JR MacFall, CE Hayes, HD Sostman and BE Slayman
Applied Science Laboratory, GE Medical Systems, Milwaukee, WI 53201.

The authors obtained magnetic resonance images of the pulmonary vasculature with reduced artifacts caused by cardiac and respiratory motion by acquiring a series of moderately thin sections in a single breath-hold with an ultrafast gradient-echo pulse sequence. The series of two-dimensional images was postprocessed with a maximum-intensity projection algorithm. Time-of-flight inflow enhancement increased the signal intensity of arteries and veins while radiofrequency phase spoiling produced limited stationary spin suppression of the chest wall. Moderately thin (8-mm) section thicknesses were used to attain the resolution necessary to visualize smaller pulmonary vascular segments up to the chest wall while the number of acquired sections was minimized. Because the body coil did not provide an adequate signal-to- noise ratio (S/N) for a single excitation and thin-section acquisitions, phased-array coils covering either the right or left lung were used to single breath-holds prevented the misregistration and blurring that occurred in examinations performed with multiple breath- holds.


This article has been cited by other articles:


Home page
NEJMHome page
J. F.M. Meaney, J. G. Weg, T. L. Chenevert, D. Stafford-Johnson, B. H. Hamilton, and M. R. Prince
Diagnosis of Pulmonary Embolism with Magnetic Resonance Angiography
N. Engl. J. Med., May 15, 1997; 336(20): 1422 - 1427.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 1992 by the Radiological Society of North America.